-47%

Schneider RE17RCMU | Off-delay timing relay – 1 s..100 h – 24..240 V AC – 1 OC

Schneider Electric
Availability:

In stock


1,420.23 EGP 2,679.68 EGP

In stock

Schneider RE17RCMU | Off-delay timing relay – 1 s..100 h – 24..240 V AC – 1 OC

 

Schneider RE17RCMU Off-Delay Timing Relay

The Schneider RE17RCMU is a reliable and versatile off-delay timing relay that offers precise timing control for various applications. Here are the key features and specifications of the RE17RCMU:

  • Timing Range: The relay provides an adjustable off-delay timing range from 1 second to 100 hours, allowing for precise control over delayed switching or timing sequences.
  • Voltage Compatibility: It is designed to operate within a wide voltage range of 24 to 240 volts AC, making it compatible with different electrical systems and applications.
  • Contact Configuration: The relay features 1 OC (normally open) contact, providing switching capability based on the configured timing parameters.
  • Modular Design: The RE17RCMU is designed for easy installation and integration into control panels or enclosures using DIN rail mounting, ensuring a space-efficient and secure setup.
  • LED Indicator: Equipped with LED status indicators for power and relay operation, providing visual feedback on the relay’s status and timing functions.
  • Versatile Applications: Suitable for various applications requiring off-delay timing control, such as motor starting delays, equipment sequencing, and process control in industrial automation.
  • Reliable Performance: Schneider Electric’s reputation for quality ensures reliable and accurate timing operations, enhancing system performance and efficiency.

Applications:

  • Industrial Automation: Used in machinery and equipment for delayed switching and timing functions related to production processes and automation sequences.
  • HVAC Systems: Applied in heating, ventilation, and air conditioning systems for delayed control of fans, compressors, and other components.
  • Process Control: Utilized in process industries for timed control of valves, pumps, and actuators based on specific time delays.
  • Lighting Control: Suitable for timed switching of lights, especially in applications requiring delayed lighting or shutdown sequences.
  • Power Management: Integrated into power distribution systems for delayed switching of circuits and equipment to manage power consumption and load sequencing.

Benefits:

  1. Precise Off-Delay Timing: Offers adjustable timing from seconds to hours for precise control over delayed operations.
  2. Wide Voltage Range: Compatible with a wide range of voltages, enhancing its versatility in different electrical systems.
  3. Reliable Operation: Schneider Electric’s quality assurance ensures reliable and consistent performance in timing functions.
  4. Easy Installation: Modular design and DIN rail mounting simplify installation and maintenance, reducing downtime.
  5. Visual Feedback: LED indicators provide clear status indication, aiding in monitoring and troubleshooting.
Main
Range of product Harmony Timer Relays
Discrete output type Relay
Product or component type Modular timing relay
Width 17.5 mm
Device short name RE17R
Time delay type Off-delay
Time delay range 6…60 s
1…10 h
1…10 min
6…60 min
0.1…1 s
1…10 s
10…100 h
Nominal output current 8 A
Complementary
Contacts type and composition 1 C/O
Contacts material Cadmium free
Height 90 mm
Depth 72 mm
Control type Selector switch front panel
[Us] rated supply voltage 24…240 V AC 50/60 Hz
24 V DC
Voltage range 0.85…1.1 Us
Supply frequency 50…60 Hz +/- 5 %
release of input voltage 10 V
Connections – terminals Screw terminals, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) solid without cable end
Screw terminals, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) solid without cable end
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) flexible with cable end
Tightening torque 0.6…1 N.m conforming to IEC 60947-1
Housing material Self-extinguishing
Repeat accuracy +/- 0.5 % conforming to IEC 61812-1
Temperature drift +/- 0.05 %/°C
Voltage drift +/- 0.2 %/V
Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Time delay type Off-delay – C- Off-delay relay w/ control signal
control signal pulse width 100 ms with load in parallel typical
30 ms typical
Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
Reset time 120 ms on de-energisation typical
On-load factor 100 %
Power consumption in VA 0…32 VA at 240 V AC
Maximum power consumption in W 0.6 W at 24 V DC
Minimum switching current 10 mA at 5 V DC
Maximum switching current 8 A AC/DC
Maximum switching voltage 250 V AC
Breaking capacity 2000 VA
operating frequency 10 Hz
Electrical durability 100000 cycles (8 A at 250 V AC maximum) for resistive load
Mechanical durability 10000000 cycles
Dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
[Uimp] rated impulse withstand voltage 5 kV during 1.2/50 µs
power on delay 100 ms
Marking CE
Creepage distance 4 kV/3 conforming to IEC 60664-1
Safety reliability data B10d = 270000
MTTFd = 296.8 years
Mounting position Any position in relation to normal vertical mounting plane
Mounting support 35 mm DIN rail conforming to IEC 60715
Local signalling LED indicator for on steady: relay energised, no timing in progress
LED indicator for flashing: timing in progress 80 % ON and 20 % OFF
LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 % ON and 95 % OFF
Function available C- Off-delay relay w/ control signal-1 C/O
Net weight 0.07 kg
Control type Without test button
Number of functions 1
Time delay type C
Functionality Off-delay timing
Compatibility code RE17
Environment
Immunity to microbreaks 20 ms
Standards IEC 61000-6-4
IEC 61000-6-2
IEC 61000-6-3
2004/108/EC
2006/95/EC
IEC 61812-1
IEC 61000-6-1
Product certifications cULus
GL
CSA
Ambient air temperature for storage -30…60 °C
Ambient air temperature for operation -20…60 °C
IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
Vibration resistance 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity 93 % without condensation conforming to IEC 60068-2-30
Electromagnetic compatibility Electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
Electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
Conducted RF disturbances: (0.15…80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
Voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
Conducted and radiated emissions: , class B, conforming to EN 55022
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.8 cm
Package 1 Width 7.4 cm
Package 1 Length 9.4 cm
Package 1 Weight 80 g
Unit Type of Package 2 S02
Number of Units in Package 2 40
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 3.706 kg

Based on 0 reviews

0.0 overall
0
0
0
0
0