The Schneider RE22R1AMR is a versatile modular timing relay engineered to provide accurate timing control in a wide range of applications. Here are its key specifications and features:

  • Timing Range: The timing relay offers a wide timing range from 0.05 seconds to 300 hours, allowing for precise control over time-sensitive operations.
  • Contact Configuration: It features 1 CO (changeover) contact, providing flexibility in switching between different circuits or devices.
  • Operating Mode: The relay is designed for power on delay, ensuring that the connected load receives power after a specified delay period.
  • Voltage Compatibility: It supports a wide voltage range of 24 to 240 volts AC/DC, making it suitable for use in various electrical systems.
  • Current Capacity: With a current rating of 8 amps, the relay can handle moderate to high current loads with ease.
  • Modular Design: The modular construction of the RE22R1AMR allows for easy integration into control panels and systems, facilitating installation and maintenance.

Applications:

  • Industrial Automation: Ideal for controlling timing sequences in industrial machinery and processes.
  • HVAC Systems: Used for time-delayed functions in heating, ventilation, and air conditioning systems.
  • Lighting Control: Provides timed switching for lighting systems in commercial and residential buildings.
  • Pump Control: Enables precise timing control for pumps and motors in water supply and wastewater systems.
  • Automated Equipment: Suitable for integrating with automated equipment and control systems requiring timed operations.

Benefits:

  1. Precision Timing: Ensures accurate and reliable timing control for critical operations.
  2. Versatility: Compatible with a wide range of voltage inputs and applications.
  3. Ease of Integration: Modular design allows for seamless integration into existing control setups.
  4. Enhanced Control: Enables power on delay functionality, enhancing control over connected loads.
  5. Durable Build: Schneider Electric’s reputation for quality ensures a durable and reliable timing relay solution.
Main
Range of product Harmony Timer Relays
Discrete output type Relay
Product or component type Modular timing relay
Device short name RE22
Nominal output current 8 A
Complementary
Contacts type and composition 1 C/O timed contact, cadmium free
Time delay type Power on-delay
Time delay range 3…30 s
30…300 s
10…100 s
0.05…1 s
1…10 s
30…300 h
30…300 min
0.3…3 s
3…30 h
3…30 min
Control type Rotary knob
Diagnostic button
[Us] rated supply voltage 24…240 V AC/DC 50/60 Hz
Release input voltage <= 2.4 V
Voltage range 0.85…1.1 Us
Supply frequency 50…60 Hz +/- 5 %
Connections – terminals Screw terminals, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) solid without cable end
Screw terminals, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) solid without cable end
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) flexible with cable end
Tightening torque 0.6…1 N.m conforming to IEC 60947-1
Housing material Self-extinguishing
Repeat accuracy +/- 0.5 % conforming to IEC 61812-1
Temperature drift +/- 0.05 %/°C
Voltage drift +/- 0.2 %/V
Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Time delay type Power on-delay – A- Power on-delay relay
Power on-delay – Aw- Power on-delay relay w/ retrigger/restart
Control signal pulse width 100 ms with load in parallel
30 ms
Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
Recovery time 120 ms on de-energisation
Immunity to microbreaks 10 ms
Power consumption in VA 3 VA at 240 V AC
Power consumption in W 1.5 W at 240 V DC
Switching capacity in VA 2000 VA
Minimum switching current 10 mA at 5 V DC
Maximum switching current 8 A
Maximum switching voltage 250 V AC
Electrical durability 100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-1
Mechanical durability 10000000 cycles
Rated impulse withstand voltage 5 kV for 1.2…50 µs conforming to IEC 60664-1
Power on delay 100 ms
Creepage distance 4 kV/3 conforming to IEC 60664-1
Overvoltage category III conforming to IEC 60664-1
Safety reliability data MTTFd = 308.2 years
B10d = 280000
Mounting position Any position
Mounting support 35 mm DIN rail conforming to IEC 60715
Status LED LED backlight green (steady) for dial pointer indication
LED yellow (steady) for output relay energised
LED yellow (fast flashing) for timing in progress and output relay de-energised
LED yellow (slow flashing) for timing in progress and output relay energised
Function available A- Power on-delay relay-1 C/O
Aw- Power on-delay relay w/ retrigger/restart-1 C/O
Width 22.5 mm
Net weight 0.1 kg
Control type With test button
Number of functions 2
Environment
Dielectric strength 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1
Standards UL 508
IEC 61812-1
Directives 2006/95/EC – low voltage directive
2004/108/EC – electromagnetic compatibility
Product certifications CE
UL
GL
CCC
EAC
RCM
CSA
Ambient air temperature for operation -20…60 °C
Ambient air temperature for storage -40…70 °C
IP degree of protection IP40 housing: conforming to IEC 60529
IP50 front face: conforming to IEC 60529
IP20 terminals: conforming to IEC 60529
Pollution degree 3 conforming to IEC 60664-1
Vibration resistance 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn not operating for 11 ms conforming to IEC 60068-2-27
5 gn in operation for 11 ms conforming to IEC 60068-2-27
Relative humidity 95 % at 25…55 °C
Electromagnetic compatibility Fast transients immunity test – test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
Surge immunity test – test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5
Surge immunity test – test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5
Electrostatic discharge – test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge – test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test – test level: 10 V/m level 3 (80 MHz…1 GHz) conforming to IEC 61000-4-3
Conducted RF disturbances – test level: 10 V level 3 (0.15…80 MHz) conforming to IEC 61000-4-6
Fast transient bursts – test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
Immunity to microbreaks and voltage drops – test level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to microbreaks and voltage drops – test level: 100 % (20 ms) conforming to IEC 61000-4-11
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.6 cm
Package 1 Width 8.2 cm
Package 1 Length 9.5 cm
Package 1 Weight 92.0 g
Unit Type of Package 2 S02
Number of Units in Package 2 40
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 4.261 kg
Unit Type of Package 3 P06
Number of Units in Package 3 640
Package 3 Height 75.0 cm
Package 3 Width 60.0 cm
Package 3 Length 80.0 cm
Package 3 Weight 76.676 kg

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider RE22R1AMR | Modular timing relay, 8 A, 0.05 s…300 h, 1 CO, power on delay , 24…240 V AC/DC”

There are no reviews yet.

SHOPPING CART

close
Let's Chat