In the realm of electrical engineering and automation, the Schneider RM22LG11MT Relay stands out as a reliable and versatile component. As technology continues to evolve, the need for efficient control systems becomes paramount, and relays play a crucial role in this domain.

What is a relay?

Definition

A relay is an electromechanical device used to control the flow of electricity in a circuit. It works by using a small current to control a larger one, allowing for the automation of various processes.

Importance

Relays are integral to numerous applications, ranging from industrial machinery to home automation systems. They provide a safe and efficient means of controlling high-power circuits without the need for manual intervention.

Overview of Schneider RM22LG11MT Relay

The Schneider RM22LG11MT Relay is renowned for its robust construction and reliable performance. Designed to meet the demands of modern automation systems, it offers a host of features that make it ideal for a wide range of applications.

Features

  • Compact design
  • Wide operating voltage range
  • DIN rail mounting
  • LED status indicators
  • High switching capacity

Applications

The RM22LG11MT Relay finds use in various industries, including:

  • Manufacturing
  • Automotive
  • Energy management
  • Building automation

Key Specifications

Voltage Rating

The relay is capable of handling voltages ranging from 24V to 240V AC/DC, making it suitable for diverse power systems.

Contact Configuration

With SPDT (Single Pole Double Throw) contact configuration, the relay offers versatility in switching operations.

Mounting Type

Designed for DIN rail mounting, the RM22LG11MT Relay can be easily integrated into control panels and enclosures.

Advantages of Schneider RM22LG11MT Relay

  • Reliable performance
  • Compact size
  • Easy installation
  • LED indicators for status monitoring
  • Wide voltage compatibility

Installation Guide

Steps

  1. Ensure power supply is disconnected.
  2. Mount the relay on a DIN rail using appropriate fasteners.
  3. Connect control and load wires as per the circuit diagram.
  4. Verify connections and secure terminal screws.
  5. Reapply power and test operation.

Safety Precautions

  • Always work on electrical systems with caution and wear appropriate protective gear.
  • Double-check wiring connections to prevent short circuits.
  • Regularly inspect the relay for signs of damage or wear.

Maintenance Tips

Cleaning

Periodically clean the relay and surrounding area to prevent dust buildup, which can affect performance.

Inspection

Inspect terminal connections and wiring for signs of corrosion or looseness. Tighten screws as needed to ensure proper contact.

Troubleshooting Common Issues

Overheating

If the relay becomes excessively hot during operation, check for overloading or poor ventilation. Consider using a relay with a higher current rating if necessary.

Contact Welding

In cases where relay contacts become welded due to high current, replace the relay with one rated for a higher switching capacity.

Comparison with Other Relays

The Schneider RM22LG11MT Relay stands out from its counterparts due to its compact size, wide voltage range, and robust construction. While other relays may offer similar features, few can match the reliability and performance of the RM22LG11MT.

Customer Reviews and Feedback

Customers praise the Schneider RM22LG11MT Relay for its durability and ease of installation. Many have noted its compatibility with various control systems and its ability to withstand harsh operating conditions.

Conclusion

In conclusion, the Schneider RM22LG11MT Relay represents a pinnacle of reliability and performance in the realm of automation. Its compact design, wide voltage compatibility, and robust construction make it an ideal choice for a multitude of applications. Whether in industrial settings or home automation projects, this relay delivers consistent and dependable operation.

Weight0.1 kg
brands

Main
Range of productHarmony Control Relays
Relay typeLevel control relay
Product or component typeLevel control relay
Relay nameRM22L
Relay monitored parametersDetection by resistive probes
time delayWithout
Switching capacity in VA2000 VA
Minimum switching current10 mA at 5 V DC
Maximum switching current8 A AC
Utilisation categoryAC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
AC-1 conforming to IEC 60947-4-1
DC-1 conforming to IEC 60947-4-1
Contacts type and composition1 C/O
Complementary
Maximum switching voltage250 V AC
[Un] rated nominal voltage380…415 V AC/DC 50/60 Hz, non self-powered
Supply voltage limits323…456.5 V AC
Output contacts2 C/O
Nominal output current8 A
delay at power up0.6 s
Maximum electrode voltage12 V AC
Maximum electrode current1 mA
Repeat accuracy+/- 2 % for time delay
Measurement error< 1 % over the whole range with voltage variation
0.05 %/°C with temperature variation
Maximum cable distance between devices1000 m between probe and delay
Sensitivity scale5…100 kOhm St (Standard Sensitivity)
Sensitivity adjustment5…100 %
Maximum supply current for sensors1 mA
Cable capacitance1 nF at HS (High Sensitivity) for probe cable
2.2 nF at St (Standard Sensitivity) for probe cable
4.7 nF at LS (Low Sensitivity) for probe cable
Overvoltage categoryIII conforming to IEC 60664-1
InsulationBetween supply and measurement
Connections – terminalsScrew terminals, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) solid without cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) flexible with cable end
Screw terminals, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) solid without cable end
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Tightening torque0.6…1 N.m conforming to IEC 60947-1
Housing materialSelf-extinguishing plastic
Mounting support35 mm DIN rail conforming to IEC 60715
Mounting positionAny position
Electrical durability100000 cycles
Mechanical durability10000000 cycles
Contacts materialCadmium free
Measurement range5…100 kOhm
Safety reliability dataMTTFd = 125.5 years
B10d = 120000
Width22.5 mm
Control typeWith test button
Net weight0.1 kg
Environment
Immunity to microbreaks100 ms DC
90 ms AC
Electromagnetic compatibilityImmunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1
Immunity for industrial environments conforming to IEC 61000-6-2
Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
Emission standard for industrial environments conforming to IEC 61000-6-4
Electrostatic discharge – test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge – test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test – test level: 10 V/m level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test – test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4
Surge immunity test – test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
Surge immunity test – test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
Conducted and radiated emissions class B group 1 conforming to CISPR 11
Conducted and radiated emissions class B conforming to CISPR 22
StandardsIEC 60255-1
Product certificationsCSA
GL
RCM
UL
EAC
CE
CCC
Ambient air temperature for storage-40…70 °C
Relative humidity93…97 % at 25…55 °C conforming to IEC 60068-2-30
Vibration resistance0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
Shock resistance15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
IP degree of protectionIP20 (terminals) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Dielectric test voltage2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.6 cm
Package 1 Width8.2 cm
Package 1 Length9.5 cm
Package 1 Weight107.0 g
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight4.711 kg
Unit Type of Package 3P06
Number of Units in Package 3640
Package 3 Height80.0 cm
Package 3 Width80.0 cm
Package 3 Length60.0 cm
Package 3 Weight84.26 kg

Main documents

DatasheetDownload Datasheet
Product datasheetRM22LG11MT
Instruction sheet
Download
CatalogDownload
Environmental disclosure
Download
CAD FilesDownload

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider RM22LG11MT Relay | Level control relay RM22-L – 380..415 V AC – 1 C/O”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat