Uncategorized
Schneider RM35ATL0MW | temperature control relay, Harmony Control Relays, 5A, 1CO, 24..240V AC DC
Availability:
In stock
Schneider RM35ATL0MW | temperature control relay, Harmony Control Relays, 5A, 1CO, 24..240V AC DC
3,898 EGP 7,086 EGP
In stock
CompareRange of Product | Harmony Control Relays |
---|---|
Relay Type | Temperature control relays |
Product or Component Type | Elevator machine room temperature control relay |
Product Specific Application | For elevator machine rooms and 3-phase supplies |
Relay name | RM35AT |
Relay monitored parameters | Undertemperature: -1…11°C Overtemperature: 34…46°C |
Time delay range | 0.1…10 s adjustable 0…10 % of the full scale value) |
Switching capacity in VA | 1250 VA |
Minimum switching current | 10 mA 5 V DC |
Maximum power consumption in VA | 3.5 VA AC |
Utilisation category | AC-12 IEC 60947-5-1 AC-13 IEC 60947-5-1 AC-14 IEC 60947-5-1 AC-15 IEC 60947-5-1 DC-12 IEC 60947-5-1 DC-13 IEC 60947-5-1 DC-14 IEC 60947-5-1 |
time delay | Adjustable 1…10 s Tt- time delay upon fault |
Measurement range | +/- 1…46 °C |
Reset time | 8 s |
---|---|
Maximum switching voltage | 250 V AC/DC |
[Us] rated supply voltage | 24…240 V AC/DC |
[Un] rated nominal voltage | 24…240 V AC/DC 50/60 Hz, non self-powered |
Supply voltage limits | 20.4…264 V AC 21.6…264 V DC |
Maximum power consumption in W | 0.6 W DC |
Resistance across terminals | 1.33 kOhm temperature |
Width | 1.4 in (35 mm) |
Output contacts | 1 C/O |
Contacts material | Cadmium free |
Nominal output current | 5 A |
delay at power up | 0.2 s |
Measurement accuracy | +/- 2 °C |
Response time | <= 3.5 s + Tt (in case of temperature fault) <= 3.5 s (on disappearance of fault) |
Temperature probe type | Pt 100 – 3-wire |
Installed device | Pt 100 probe cable length <= 10 m |
Marking | CE : EMC 89/336/EEC CE : 73/23/EEC |
Overvoltage category | III IEC 60664-1 |
Insulation resistance | > 500 MOhm 500 V DC between supply and relay output IEC 60255-5 > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 > 500 MOhm 500 V DC between supply and relay output IEC 60664-1 > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5 > 1 MOhm 500 V DC between supply and measurement IEC 60664-1 |
[Ui] rated insulation voltage | 250 V IEC 60664-1 |
operating voltage tolerance | – 10 % + 10 % Un DC – 15 % + 10 % Un AC |
Supply frequency | 50/60 Hz +/- 10 % |
Insulation | Galvanic insulation between supply and measurement |
Operating position | Any position without derating |
Connections – terminals | Screw terminals, 1 x 0.5…1 x 4 mm² AWG 20…AWG 11) solid without cable end Screw terminals, 2 x 0.5…2 x 2.5 mm² AWG 20…AWG 14) solid without cable end Screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 24…AWG 12) flexible with cable end Screw terminals, 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16) flexible with cable end |
Tightening torque | 5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1 |
Housing material | Self-extinguishing plastic |
local signalling | 1 LED Green power ON 1 LED Yellow correct temperature (high R1) 1 LED Yellow correct temperature (low R2) |
Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
Electrical durability | 100000 cycles |
Mechanical durability | 30000000 cycles |
Operating rate | <= 360 operations/hour full load |
Control Type | Without test button |
Immunity to microbreaks | 10 ms |
---|---|
Electromagnetic compatibility | Emission standard for industrial environments IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments IEC 61000-6-3 Immunity for industrial environments NF EN/IEC 61000-6-2 |
Standards | IEC 60255-6 NF EN 60255-6 |
Product Certifications | GOST GL C-tick UL CSA |
Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) |
Ambient Air Temperature for Operation | -4…122 °F (-20…50 °C) |
Vibration resistance | 0.35 mm 5…57.6 Hz)IEC 60068-2-6/IEC 60255-21-1 1 gn 57.6…150 Hz)IEC 60068-2-6/IEC 60255-21-1 |
Shock resistance | 15 gn 11 ms IEC 60255-21-1 |
IP degree of protection | IP20 IEC 60529 terminals) IP30 IEC 60529 casing) |
Pollution degree | 3 IEC 60664-1 |
Dielectric test voltage | 2 kV AC 50 Hz, 1 min |
Non-dissipating shock wave | 4 kV |
Category | US10CP222380 |
---|---|
Discount Schedule | 0CP2 |
GTIN | 3389119405164 |
Returnability | No |
Country of origin | ID |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 3.1 in (8.0 cm) |
Package 1 Width | 1.8 in (4.6 cm) |
Package 1 Length | 3.8 in (9.7 cm) |
Package 1 Weight | 4.5 oz (127.0 g) |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 48 |
Package 2 Height | 11.8 in (30.0 cm) |
Package 2 Width | 11.8 in (30.0 cm) |
Package 2 Length | 15.7 in (40.0 cm) |
Package 2 Weight | 14.842 lb(US) (6.732 kg) |
Warranty | 18 months |
---|