Let's Chat
-45%

Schneider RUMC21JD | universal plug-in relay – Harmony RUM – 2 C/O – 12 V DC – 10 A

Schneider Electric
Availability:

In stock


Schneider RUMC21JD | universal plug-in relay – Harmony RUM – 2 C/O – 12 V DC – 10 A

352 EGP 640 EGP

In stock

Compare

Schneider RUMC21JD | universal plug-in relay – Harmony RUM – 2 C/O – 12 V DC – 10 A

Schneider RUMC21JD: Comprehensive Guide to Versatile Relays

Introduction

Relays play a critical role in electrical systems, providing the necessary switching mechanisms that ensure seamless operation. The Schneider RUMC21JD is one such relay, offering reliability and versatility. But why are relays so essential, and what makes the RUMC21JD a noteworthy option? Let’s explore these questions in detail.

What is the Schneider RUMC21JD?

The Schneider RUMC21JD is a general-purpose relay designed for a wide range of applications. It is known for its reliability and robust performance, making it a go-to choice for various electrical systems.

Key Features

  • High Switching Capacity: Capable of handling high loads.
  • Compact Design: Fits easily into different configurations.
  • Versatile Use: Suitable for various applications, from industrial to residential.

Technical Specifications

Understanding the technical details can provide insights into the RUMC21JD’s capabilities:

  • Electrical Specifications: Rated operational voltage of up to 250V AC/DC, with a current rating of 10A.
  • Physical Dimensions: Compact size with standard pin configurations for easy integration.

Benefits of Using Schneider RUMC21JD

Why should you consider the RUMC21JD for your relay needs? Here are some compelling reasons:

  • Enhanced Reliability: Designed to perform consistently under various conditions.
  • Versatile Applications: Suitable for use in different environments, ensuring flexibility in application.

Installation and Setup

Installing the RUMC21JD is straightforward. Here’s a simple guide:

Pre-installation Checklist:

  • Ensure the power is off.
  • Verify the specifications match the system requirements.

Step-by-step Installation Guide:

  1. Mount the relay onto the designated slot or socket.
  2. Connect the wiring according to the provided schematic.
  3. Secure the relay and test the connections.
  4. Power on the system and test the relay’s operation.

How Schneider RUMC21JD Works

The RUMC21JD operates by utilizing an electromagnetic coil to open or close contacts, allowing or interrupting the flow of electricity.

Contact Configuration:

  • DPDT (Double Pole Double Throw): Offers multiple switching options for versatile use.

Applications of Schneider RUMC21JD

This versatile relay is suitable for various settings:

Industrial Use:

  • Automation systems
  • Control panels

Commercial Use:

  • HVAC systems
  • Lighting control

Residential Use:

  • Home automation
  • Security systems
SKU: RUMC21JD Category:
Main
Range of product Harmony Electromechanical Relays
Series name Universal
Product or component type Plug-in relay
Device short name RUM
Contacts type and composition 2 C/O
[Uc] control circuit voltage 12 V DC
[Ithe] conventional enclosed thermal current 10 A at -40…55 °C
Status LED Without
Control type Lockable test button
Utilisation coefficient 20 %
Complementary
Shape of pin Cylindrical
[Ui] rated insulation voltage 250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
[Uimp] rated impulse withstand voltage 4 kV (1.2/50 µs)
Contacts material AgNi
[Ie] rated operational current 10 A at 277 V AC conforming to UL
10 A at 30 V DC conforming to UL
10 A at 30 V DC conforming to CSA
5 A at 250 V AC (NC) conforming to IEC
5 A at 28 V DC (NC) conforming to IEC
10 A at 250 V AC (NO) conforming to IEC
10 A at 28 V DC (NO) conforming to IEC
10 A at 277 V AC conforming to CSA
Maximum switching voltage 250 V conforming to IEC
Resistive rated load 10 A at 250 V AC
10 A at 28 V DC
Maximum switching capacity 2500 VA/280 W
Minimum switching capacity 170 mW at 10 mA, 17 V
Operating rate <= 18000 cycles/hour no-load
<= 1200 cycles/hour under load
Mechanical durability 5000000 cycles
Electrical durability 100000 cycles for resistive load
Average coil consumption in W 1.4 W
Drop-out voltage threshold >= 0.1 Uc DC
Operate time 20 ms at nominal voltage
Release time 20 ms at nominal voltage
Average coil resistance 120 Ohm at 20 °C +/- 15 %
Rated operational voltage limits 9.6…13.2 V DC
Protection category RT I
Test levels Level A group mounting
Safety reliability data B10d = 100000
Operating position Any position
Net weight 0.086 kg
device presentation Complete product
Environment
Dielectric strength 1500 V AC between contacts with micro disconnection
2500 V AC between coil and contact with reinforced
2000 V AC between poles with basic
Product certifications UL
CSA
EAC
Standards UL 508
CSA C22.2 No 14
IEC 61810-1
ambient air temperature for storage -40…85 °C
Ambient air temperature for operation -40…55 °C
Vibration resistance 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation
4 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating
IP degree of protection IP40
Shock resistance 10 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
10 gn (duration = 11 ms) for not operating conforming to IEC 60068-2-27
Pollution degree 3
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 3.7 cm
Package 1 Width 3.8 cm
Package 1 Length 7.2 cm
Package 1 Weight 95.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 10
Package 2 Height 4.0 cm
Package 2 Width 14.6 cm
Package 2 Length 20.0 cm
Package 2 Weight 937.0 g
Unit Type of Package 3 S02
Number of Units in Package 3 60
Package 3 Height 15.0 cm
Package 3 Width 30.0 cm
Package 3 Length 40.0 cm
Package 3 Weight 6.042 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider RUMC21JD | universal plug-in relay – Harmony RUM – 2 C/O – 12 V DC – 10 A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024