-45%
, , ,

Schneider RUMC31E7 | universal plug-in relay – Harmony RUM – 3 C/O – 48 V AC – 10 A

Schneider Electric

Schneider RUMC31E7 | universal plug-in relay – Harmony RUM – 3 C/O – 48 V AC – 10 A

395 EGP 718 EGP

Compare

Schneider RUMC31E7 | universal plug-in relay – Harmony RUM – 3 C/O – 48 V AC – 10 A

Technical Specifications

  • Model: RUMC31E7
  • Series: Harmony RUM
  • Relay Type: Universal Plug-In Relay
  • Number of Contacts: 3 Changeover (3 C/O)
  • Coil Voltage: 48V AC
  • Current Rating: 10A
  • Contact Type: Silver alloy (AgNi), ensuring long lifespan and excellent conductivity
  • Electrical Durability: High switching capacity for industrial applications
  • Mounting Type: Plug-in with compatible relay socket
  • Standards & Certifications: CE, UL, IEC, RoHS compliant

Key Features

1. Versatile and Reliable Performance

  • Suitable for switching and controlling electrical circuits in a variety of applications.
  • High current rating (10A) allows for operation with various loads.

2. Durable and High-Quality Design

  • Built with silver alloy contacts (AgNi) for improved durability and efficient electrical conductivity.
  • Ensures long electrical and mechanical lifespan, reducing maintenance requirements.

3. Easy Installation and Compatibility

  • Plug-in design allows for quick and effortless installation in compatible relay sockets.
  • Compatible with Harmony RUM relay sockets, making it easy to integrate into existing systems.

4. Wide Range of Industrial Applications

  • Ideal for use in industrial automation, machine control, power distribution, and HVAC systems.
  • Reliable performance in high-demand environments, ensuring operational efficiency.

Applications

The Schneider RUMC31E7 relay is widely used in various industries and applications, including:

Industrial Automation – Used in control panels, PLC interfaces, and motor control systems.
Electrical Distribution – Suitable for switching power circuits and control circuits.
Machine Control – Ideal for machinery, robotics, and production lines.
HVAC Systems – Used in heating, ventilation, and air conditioning applications.
Building Management Systems – Helps in controlling lighting, security systems, and automated functions.

brands

Main
Range of productHarmony Electromechanical Relays
Series nameUniversal
Product or component typePlug-in relay
Device short nameRUM
Contacts type and composition3 C/O
[Uc] control circuit voltage48 V AC 50/60 Hz
[Ithe] conventional enclosed thermal current10 A at -40…55 °C
status LEDWithout
control typeLockable test button
Utilisation coefficient20 %
Complementary
Shape of pinCylindrical
[Ui] rated insulation voltage250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
[Uimp] rated impulse withstand voltage4 kV (1.2/50 µs)
Contacts materialAgNi
[Ie] rated operational current10 A at 277 V AC conforming to UL
10 A at 30 V DC conforming to UL
10 A at 277 V AC (same polarity) conforming to CSA
10 A at 30 V DC conforming to CSA
5 A at 250 V AC (NC) conforming to IEC
5 A at 28 V DC (NC) conforming to IEC
10 A at 250 V AC (NO) conforming to IEC
10 A at 28 V DC (NO) conforming to IEC
Maximum switching voltage250 V conforming to IEC
Resistive rated load10 A at 250 V AC
10 A at 28 V DC
Maximum switching capacity2500 VA/280 W
Minimum switching capacity170 mW at 10 mA, 17 V
Operating rate<= 18000 cycles/hour no-load
<= 1200 cycles/hour under load
Mechanical durability5000000 cycles
Electrical durability100000 cycles for resistive load
Average coil consumption in VA3 at 60 Hz
Drop-out voltage threshold>= 0.15 Uc AC
Operate time20 ms at nominal voltage
Release time20 ms at nominal voltage
Average coil resistance290 Ohm at 20 °C +/- 15 %
Rated operational voltage limits38.4…52.8 V AC
Protection categoryRT I
Test levelsLevel A group mounting
Safety reliability dataB10d = 100000
Operating positionAny position
Product weight0.086 kg
Device presentationComplete product
Environment
Dielectric strength1500 V AC between contacts with micro disconnection
2500 V AC between coil and contact with reinforced
2000 V AC between poles with basic
Product certificationsUL
CSA
EAC
StandardsIEC 61810-1
CSA C22.2 No 14
UL 508
Ambient air temperature for storage-40…85 °C
Ambient air temperature for operation-40…55 °C
Vibration resistance3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation
4 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating
IP degree of protectionIP40
Shock resistance10 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
10 gn (duration = 11 ms) for not operating conforming to IEC 60068-2-27
pollution degree2
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height3.500 cm
Package 1 Width6.900 cm
Package 1 Length3.600 cm
Package 1 Weight91.000 g
Unit Type of Package 2BB1
Number of Units in Package 210
Package 2 Height4.000 cm
Package 2 Width14.600 cm
Package 2 Length20.000 cm
Package 2 Weight996.000 g
Unit Type of Package 3S02
Number of Units in Package 360
Package 3 Height15.000 cm
Package 3 Width30.000 cm
Package 3 Length40.000 cm
Package 3 Weight6.481 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider RUMC31E7 | universal plug-in relay – Harmony RUM – 3 C/O – 48 V AC – 10 A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat