-45%
,

Schneider TM100C16RN | Controller M100 – 9I/7O relay – 220VAC

Schneider Electric
Availability:

In stock


Schneider TM100C16RN | Controller M100 – 9I/7O relay – 220VAC

11,593 EGP 21,079 EGP

In stock

Compare

Schneider TM100C16RN | Controller M100 – 9I/7O relay – 220VAC

The Schneider TM100C16RN is a versatile programmable logic controller (PLC) from the Modicon M100 series. It is designed for small to medium-scale automation tasks and is especially suited for controlling relay-based applications. With its 9 inputs and 7 outputs, this controller is ideal for simple process automation in industrial environments, operating with 220V AC input power.

Key Features

  • Product Type: Programmable Logic Controller (PLC)

  • Series: Modicon M100

  • I/O Configuration:

    • Inputs: 9 digital inputs

    • Outputs: 7 relay outputs (normally open)

  • Input Voltage: 220V AC

  • Output Voltage: 220V AC (relay-based)

  • Programming Software: Can be programmed using the SoMachine or other compatible software solutions for ease of setup and configuration.

  • Relay Outputs: Capable of switching AC devices, ideal for applications that require relay-based output control.

  • Mounting: Compact design allows for easy integration into control panels.

  • Communication Ports: Includes standard connection options for simple programming and communication.

  • Protection Rating: IP20, suitable for installation in a controlled environment.

  • Operating Temperature: 0°C to 55°C

  • Dimensions: Compact and efficient design for space-constrained installations.

Applications

The TM100C16RN is suitable for controlling a wide range of automation processes in various industries, including:

  • Lighting Control: Managing lighting systems in industrial or commercial settings.

  • Water Treatment Plants: Controlling pumps, valves, and other equipment.

  • Conveyor Systems: Overseeing material handling and sorting processes.

  • HVAC Systems: Automating heating, ventilation, and air conditioning systems.

  • Pump Stations: Monitoring and controlling the operation of pumps in water and fluid management systems.

  • Manufacturing Processes: Managing smaller scale automation processes in production lines.

Advantages

  • Compact and Reliable: Small form factor and robust construction, making it ideal for space-limited environments and industrial settings.

  • Flexible I/O: The 9 inputs and 7 outputs provide sufficient flexibility for simple automation and control tasks.

  • Easy Integration: Compatible with Schneider Electric’s SoMachine software, allowing easy setup, programming, and maintenance.

  • High-Voltage Operation: The 220V AC operation allows it to directly control devices that operate on AC power, simplifying system integration.

  • Cost-Effective Solution: Offers a budget-friendly option for small to medium automation projects without sacrificing performance.

SKU: TM100C16RN Categories: , Brand:
Main
range of productEasy Modicon M100
Product or component typeLogic controller
[Us] rated supply voltage100…240 V AC
Discrete I/O number16
Discrete input numberI2…I5: 4 fast input
I6…I8: 3 regular input
I0…I1: 2 high speed input
Discrete output number7 relay
Discrete input voltage24 V
discrete input voltage typeDC
Discrete input current7 mA for regular input
7 mA for fast input
9 mA for high speed input
Discrete output voltage24 V DC
220 V AC
Discrete output current2 A
Discrete output typeRelay normally open
Power consumption in VA30…40 VA at 100…240 V AC (with max I/O)
Complementary
Supply voltage limits85…264 V
Voltage state 1 guaranteed>= 15 V for input
Voltage state 0 guaranteed<= 5 V for input
Network frequency50/60 Hz
Inrush current50 A
Input impedance3.3 kOhm for regular input
3.3 kOhm for fast input
2.81 kOhm for high speed input
Response time10 ms turn-on, Q0…Q6 terminal(s) for relay output
10 ms turn-off, Q0…Q6 terminal(s) for relay output
35 µs turn-on, I2…I5 terminal(s) for fast input
100 µs turn-off, I2…I5 terminal(s) for fast input
5 µs turn-on, I0…I1 terminal(s) for high speed input
5 µs turn-off, I0…I1 terminal(s) for high speed input
35 µs turn-on, I6…I8 terminal(s) for regular input
100 µs turn-off, I6…I8 terminal(s) for regular input
Configurable filtering time0 ms for input
3 ms for input
12 ms for input
Output voltage limits30 V DC
250 V AC
Maximum current per output common4 A at COM 0
4 A at COM 1
Electrical durability100000 cycles AC-12, 240 V, 480 VA, resistive
100000 cycles DC-12, 24 V, 48 W, resistive
Switching frequency0.1 Hz with maximum load
5 Hz without maximum load
Mechanical durability20000000 cycles for relay output
Minimum load10 mA at 5 V DC for relay output
Memory capacity1024 kB internal flash with 10000 instructions for backup of programs
Data storage equipment32 GB micro SD card (optional)
Execution time for 1 KInstruction0.3 ms for event and periodic task
Execution time per instruction0.2 µs Boolean
Exct time for event task60 µs response time
Regulation loopAdjustable PID regulator up to 14 simultaneous loops
Control signal typeQuadrature (x1, x2, x4) at 60 kHz for fast input (HSC mode)
Pulse/direction at 60 kHz for fast input (HSC mode)
Single phase at 60 kHz for fast input (HSC mode)
CW/CCW at 60 kHz for fast input (HSC mode)
Counting input number2 fast input (HSC mode) at 60 kHz 32 bits
Integrated connection typeUSB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with terminal block connector and RS485 interface
Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface
Transmission rate1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
12 Mbit/s for USB
Communication port protocolUSB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
Local signalling1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (green) for SL1
1 LED per channel (green) for I/O state
Electrical connectionRemovable screw terminal blockfor inputs
removable screw terminal blockfor outputs
removable screw terminal block, 4 terminal(s) for connecting the serial link1
Mini B USB 2.0 connectorfor a programming terminal
removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply
Maximum cable distance between devicesShielded cable: <10 m for fast input
Shielded cable: <10 m for high speed input
Unshielded cable: <150 m for output
Unshielded cable: <50 m for regular input
InsulationBetween input and internal logic at 560 V AC
Between fast input and internal logic at 560 V AC
Between input groups at 560 V AC
Non-insulated between inputs
Between output and internal logic at 1780 V AC
Between output groups at 1780 V AC
Between supply and internal logic at 1780 V AC
Sensor power supply24 V DC
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715
height90 mm
Depth70 mm
Width110 mm
Net weight0.31 kg
Environment
IP degree of protectionIP20 with protective cover in place
product certificationsCE
StandardsEN/IEC 61010-2-201
EN/IEC 61131-2
Electromagnetic compatibilityElectrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to EN/IEC 61000-4-3
Conducted emission – test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Conducted emission – test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Radiated emission – test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Radiated emission – test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Magnetic field at power frequency – test level: 30 A/m (I/O) conforming to EN/IEC 61000-4-8
Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 0.5 kV class A (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV class A (power lines (AC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (relay output) conforming to EN/IEC 61000-4-5
Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6
Shock resistance15 gn for 11 ms
30 gn for 6 ms
Immunity to microbreaks10 ms
Vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail
1 gn at 8.4…150 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
3 gn at 8.4…150 Hz on panel mounting
Relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
Ambient air temperature for operation0…55 °C (horizontal installation)
Ambient air temperature for storage-25…70 °C
Pollution degree<= 2
Operating altitude0…2000 m
Storage altitude0…3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.493 cm
Package 1 Width12.157 cm
Package 1 Length13.668 cm
Package 1 Weight450 g
Unit Type of Package 2S03
Number of Units in Package 218
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight8600 g
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height95 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight215400 g

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider TM100C16RN | Controller M100 – 9I/7O relay – 220VAC”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat