-45%
,

Schneider TM100C40RN | Controller M100 – 24I/16O relay – 220VAC

Schneider Electric
Availability:

In stock


Schneider TM100C40RN | Controller M100 – 24I/16O relay – 220VAC

15,349 EGP 27,907 EGP

In stock

Compare

Schneider TM100C40RN | Controller M100 – 24I/16O relay – 220VAC

The Schneider TM100C40RN is a programmable logic controller (PLC) from the Modicon M100 series, designed for more complex and demanding automation tasks. With 24 digital inputs and 16 relay outputs, this controller offers a higher degree of flexibility and control, making it suitable for a wide range of industrial applications. It operates with a 220V AC input power supply, ensuring compatibility with a variety of AC-powered devices.

Key Features

  • Product Type: Programmable Logic Controller (PLC)

  • Series: Modicon M100

  • I/O Configuration:

    • Inputs: 24 digital inputs

    • Outputs: 16 relay outputs (normally open)

  • Input Voltage: 220V AC

  • Output Voltage: 220V AC (relay-based)

  • Programming Software: Compatible with SoMachine or other Schneider Electric programming tools for easy configuration.

  • Relay Outputs: Provides control for AC devices, offering flexibility for various applications requiring relay-based switching.

  • Mounting: Compact and modular design for easy installation in control panels.

  • Protection Rating: IP20, making it suitable for installation in industrial control environments.

  • Operating Temperature: 0°C to 55°C

  • Dimensions: Designed to fit standard control panel sizes, optimizing space utilization.

Applications

The TM100C40RN is suitable for a wide range of applications, particularly in industries where multiple inputs and outputs are required for controlling devices. Key applications include:

  • Industrial Automation: Managing machines, conveyors, and automated equipment.

  • HVAC Systems: Control of heating, ventilation, and air conditioning in large buildings or industrial plants.

  • Water Treatment: Managing pumps, valves, and other equipment in water and waste management systems.

  • Manufacturing and Production Lines: Overseeing processes that require more complex control with multiple inputs and outputs.

  • Lighting and Energy Management: Controlling lighting systems, energy distribution, and optimization in industrial or commercial settings.

  • Elevator Systems: Managing the operation of lifts, escalators, and other elevator systems.

  • Pump Stations: Automating the operation of pumps and fluid management systems.

Advantages

  • High I/O Capacity: With 24 digital inputs and 16 relay outputs, the TM100C40RN can handle more complex automation tasks and control multiple devices simultaneously.

  • Flexibility: The relay outputs provide the ability to control various AC-powered devices, offering versatility in different applications.

  • Compact Design: The small footprint makes it ideal for integration into existing control panels without requiring excessive space.

  • Robust Performance: It’s built to work in demanding industrial environments, ensuring reliability and long-term operation.

  • Easy Programming: Schneider Electric’s SoMachine software simplifies the configuration and programming process, making it easier to set up and maintain the controller.

  • Wide Voltage Range: The 220V AC operation ensures that this PLC can directly control devices that run on standard AC power, reducing the need for additional converters or adapters.

SKU: TM100C40RN Categories: , Brand:
Main
range of productEasy Modicon M100
Product or component typeLogic controller
[Us] rated supply voltage100…240 V AC
Discrete I/O number40
Discrete input numberI2…I5: 4 fast input
I0…I1: 2 high speed input
I6…I23: 18 regular input
Discrete output number16 relay
Discrete input voltage24 V
discrete input voltage typeDC
Discrete input current7 mA for regular input
7 mA for fast input
9 mA for high speed input
Discrete output voltage24 V DC
220 V AC
Discrete output current2 A
discrete output typeRelay normally open
Power consumption in VA35…45 VA at 100…240 V AC (with max I/O)
Complementary
Supply voltage limits85…264 V
Voltage state 1 guaranteed>= 15 V for input
Voltage state 0 guaranteed<= 5 V for input
Network frequency50/60 Hz
Inrush current50 A
Input impedance3.3 kOhm for regular input
3.3 kOhm for fast input
2.81 kOhm for high speed input
Response time35 µs turn-on, I2…I5 terminal(s) for fast input
100 µs turn-off, I2…I5 terminal(s) for fast input
5 µs turn-on, I0…I1 terminal(s) for high speed input
5 µs turn-off, I0…I1 terminal(s) for high speed input
35 µs turn-on, I6…I13 terminal(s) for regular input
100 µs turn-off, I6…I13 terminal(s) for regular input
10 ms turn-on, Q0…Q15 terminal(s) for relay output
10 ms turn-off, Q0…Q15 terminal(s) for relay output
55 µs turn-on, I14…I23 terminal(s) for regular input
125 µs turn-off, I14…I23 terminal(s) for regular input
Configurable filtering time0 ms for input
3 ms for input
12 ms for input
Output voltage limits30 V DC
250 V AC
Maximum current per output common4 A at COM 0
4 A at COM 1
4 A at COM 2
4 A at COM 3
Electrical durability100000 cycles AC-12, 240 V, 480 VA, resistive
100000 cycles DC-12, 24 V, 48 W, resistive
Switching frequency0.1 Hz with maximum load
5 Hz without maximum load
Mechanical durability20000000 cycles for relay output
Minimum load10 mA at 5 V DC for relay output
Memory capacity1024 kB internal flash with 10000 instructions for backup of programs
Data storage equipment32 GB micro SD card (optional)
Execution time for 1 KInstruction0.3 ms for event and periodic task
Execution time per instruction0.2 µs Boolean
Exct time for event task60 µs response time
Clock drift<= 90 s/month at 25 °C
Regulation loopAdjustable PID regulator up to 14 simultaneous loops
Control signal typeQuadrature (x1, x2, x4) at 60 kHz for fast input (HSC mode)
Pulse/direction at 60 kHz for fast input (HSC mode)
Single phase at 60 kHz for fast input (HSC mode)
CW/CCW at 60 kHz for fast input (HSC mode)
Counting input number2 fast input (HSC mode) at 60 kHz 32 bits
Integrated connection typeUSB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with terminal block connector and RS485 interface
Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface
Transmission rate1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
12 Mbit/s for USB
Communication port protocolUSB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
Local signalling1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (green) for SL1
1 LED per channel (green) for I/O state
Electrical connectionRemovable screw terminal blockfor inputs
removable screw terminal blockfor outputs
removable screw terminal block, 4 terminal(s) for connecting the serial link1
Mini B USB 2.0 connectorfor a programming terminal
removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply
Maximum cable distance between devicesShielded cable: <10 m for fast input
Shielded cable: <10 m for high speed input
Unshielded cable: <150 m for output
Unshielded cable: <50 m for regular input
InsulationBetween input and internal logic at 560 V AC
Between fast input and internal logic at 560 V AC
Between input groups at 560 V AC
Non-insulated between inputs
Between output and internal logic at 1780 V AC
Between output groups at 1780 V AC
Between supply and internal logic at 1780 V AC
Sensor power supply24 V DC
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715
height90 mm
Depth70 mm
Width175 mm
Net weight0.409 kg
Environment
IP degree of protectionIP20 with protective cover in place
product certificationsCE
StandardsEN/IEC 61131-2
EN/IEC 61010-2-201
Electromagnetic compatibilityElectrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to EN/IEC 61000-4-3
Conducted emission – test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Conducted emission – test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Radiated emission – test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Radiated emission – test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Magnetic field at power frequency – test level: 30 A/m (I/O) conforming to EN/IEC 61000-4-8
Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 0.5 kV class A (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV class A (power lines (AC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (relay output) conforming to EN/IEC 61000-4-5
Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6
Shock resistance15 gn for 11 ms
30 gn for 6 ms
Immunity to microbreaks10 ms
Vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail
1 gn at 8.4…150 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
3 gn at 8.4…150 Hz on panel mounting
Relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
Ambient air temperature for operation0…55 °C (horizontal installation)
Ambient air temperature for storage-25…70 °C
Pollution degree<= 2
Operating altitude0…2000 m
Storage altitude0…3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height13.6 cm
Package 1 Width9.0 cm
Package 1 Length18.3 cm
Package 1 Weight658.0 g
Unit Type of Package 2S03
Number of Units in Package 212
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight8.396 kg
Unit Type of Package 3P12
Number of Units in Package 3288
Package 3 Height105.0 cm
Package 3 Width80.0 cm
Package 3 Length120.0 cm
Package 3 Weight140.0 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider TM100C40RN | Controller M100 – 24I/16O relay – 220VAC”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat