Schneider TM200C60R Description

Introduction

Schneider Electric is a global leader in energy management and automation solutions. Their products are designed to enhance efficiency and sustainability across various industries. One such product is the TM200C60R, a versatile and robust module that offers extensive capabilities for automation systems. In this article, we will provide a comprehensive overview of the Schneider TM200C60R, exploring its features, applications, and benefits.

What is the Schneider TM200C60R?

The Schneider TM200C60R is a powerful logic controller module designed to optimize and streamline automation processes. It is part of Schneider’s Modicon M200 series, known for its flexibility, performance, and ease of use. This module is ideal for applications requiring reliable control and monitoring capabilities.

Key Features

  • Integrated I/O: Equipped with 36 digital inputs and 24 relay outputs, allowing for extensive control and monitoring.
  • Compact Design: The small footprint makes it easy to integrate into various control panels and systems.
  • High Performance: Ensures fast and accurate processing of control tasks.

Technical Specifications

Understanding the technical specifications of the TM200C60R is crucial for ensuring it meets your system’s requirements.

Dimensions and Weight

  • Height: 90 mm
  • Width: 200 mm
  • Depth: 60 mm
  • Weight: 500 g

Power Requirements

  • Voltage: 24 V DC
  • Current Consumption: 350 mA

Connectivity Options

  • Communication Ports: Ethernet, Serial (RS485)
  • Input/Output Channels: 36 digital inputs, 24 relay outputs

Installation and Setup

Installing the TM200C60R is straightforward, but it’s essential to follow the guidelines to ensure optimal performance.

Pre-Installation Requirements

  • Tools Needed: Screwdriver, Multimeter
  • Environmental Conditions: Temperature range of -10°C to 50°C

Step-by-Step Installation Guide

  1. Power Down: Ensure the system is powered down before installation.
  2. Mounting: Secure the module using the provided screws.
  3. Wiring: Connect the input and output wires according to the wiring diagram.
  4. Power Up: Once connected, power up the system and verify proper operation.

Performance and Efficiency

The TM200C60R module is designed for high performance and efficiency, making it ideal for various automation needs.

Operational Capabilities

  • Processing Speed: High-speed processing for real-time control applications.
  • Load Capacity: Supports up to 2A per output channel

Energy Efficiency

  • Low Power Consumption: Designed to minimize energy usage, contributing to overall system efficiency.

Applications of TM200C60R

The TM200C60R module is versatile, making it suitable for a variety of applications across different industries.

Industrial Uses

  • Manufacturing: Enhances automation processes and improves production efficiency.
  • Energy Management: Helps in monitoring and controlling energy usage.

Commercial Applications

  • Building Automation: Integrates with building management systems for improved control.
  • HVAC Systems: Used in heating, ventilation, and air conditioning systems for better performance.

Case Studies

  • Case Study 1: A manufacturing plant improved its production line efficiency by 25% after integrating the TM200C60R.
  • Case Study 2: A commercial building reduced its energy consumption by 20% using the TM200C60R in its HVAC system.

Advantages of Using TM200C60R

Investing in the TM200C60R module offers several benefits that can significantly enhance your system’s performance.

Enhanced Productivity

  • Streamlined Operations: Simplifies processes and reduces manual intervention.
  • Real-Time Monitoring: Provides immediate feedback, allowing for quick adjustments.

Cost-Effectiveness

  • Reduced Downtime: Reliable operation minimizes system downtime.
  • Lower Energy Bills: Energy-efficient design reduces operational costs.

Integration with Other Schneider Products

The TM200C60R is designed to seamlessly integrate with other Schneider Electric products, allowing for scalable and versatile automation solutions.

Compatibility

  • Schneider PLCs: Easily integrates with Schneider programmable logic controllers.
  • EcoStruxure™: Compatible with Schneider’s EcoStruxure™ platform for enhanced control and monitoring.

System Expansion

  • Modular Design: Allows for easy addition of more modules as needed.
  • Future-Proof: Designed to support future upgrades and expansions.
SKU: TM200C60R Category:
brands

Main
Range of productEasy Modicon M200
Product or component typeLogic controller
[Us] rated supply voltage220 V AC
Discrete I/O number60
Discrete input numberI2…I5: 4 fast input
I0, I1, I6, I7: 4 high speed input
I8…I35: 28 regular input
Discrete output number24 relay
Discrete input voltage24 V
Discrete input voltage typeDC
Discrete input current7 mA for input
Discrete input logicSink or source (positive/negative) type 1 conforming to IEC 61131-2
Discrete output voltage24 V DC
220 V AC
Discrete output current2 A
Discrete output typeRelay normally open
Power consumption in VA61…74 VA at 100…240 V AC (with max I/O)
Complementary
Maximum number of I/O expansion module4 with 128 discrete output(s) for transistor output
4 with 88 discrete output(s) for relay output
Supply voltage limits85…264 V
Inrush current50 A
Voltage state 1 guaranteed>= 15 V for input
Voltage state 0 guaranteed<= 5 V for input
Input impedance3.3 kOhm for discrete input
Response time10 ms turn-on, Q0…Q23 terminal(s) for output
10 ms turn-off, Q0…Q23 terminal(s) for output
5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input
5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input
100 µs turn-off, I2…I5 terminal(s) for fast input
35 µs turn-on, I2…I5 terminal(s) for fast input
100 µs turn-off, I8…I13 terminal(s) for regular input
35 µs turn-on, I8…I13 terminal(s) for regular input
125 µs turn-off, I14…I35 terminal(s) for regular input
55 µs turn-on, I14…I35 terminal(s) for regular input
Configurable filtering time0 ms for input
3 ms for input
12 ms for input
Output voltage limits30 V DC
250 V AC
Maximum current per output common4 A at COM 2
4 A at COM 0
4 A at COM 1
4 A at COM 3
4 A at COM 4
4 A at COM 5
Electrical durability100000 cycles AC-12, 240 V, 480 VA, resistive
100000 cycles DC-12, 24 V, 48 W, resistive
Switching frequency0.1 Hz with maximum load
Mechanical durability20000000 cycles for relay output
Minimum load10 mA at 5 V DC for relay output
Memory capacity512 byte internal flash for backup of programs
Data storage equipment32 GB micro SD card (optional)
Battery typeBR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s)
Backup time3 years at 25 °C (by interruption of power supply)
Execution time for 1 KInstruction0.3 ms for event and periodic task
Execution time per instruction0.2 µs Boolean
Exct time for event task60 µs response time
Clock drift<= 90 s/month at 25 °C
Regulation loopAdjustable PID regulator up to 14 simultaneous loops
Control signal typeQuadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode)
Pulse/direction at 100 kHz for fast input (HSC mode)
Single phase at 100 kHz for fast input (HSC mode)
CW/CCW at 100 kHz for fast input (HSC mode)
Counting input number4 fast input (HSC mode) at 100 kHz 32 bits
Integrated connection typeUSB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with terminal block connector and RS485 interface
Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface
Ethernet Modbus TCP/IP Ethernet with RJ45 connector and 1 Ethernet port 10/100BASE-T interface
Isolated serial link serial 2 with terminal block connector and RS485 interface
Transmission rate1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
12 Mbit/s for USB
Communication port protocolUSB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
Local signalling1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED per channel (green) for I/O state
Electrical connectionMini B USB 2.0 connectorfor a programming terminal
removable screw terminal blockfor inputs
removable screw terminal blockfor outputs
removable screw terminal block, 4 terminal(s) for connecting the serial link1
removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply
Maximum cable distance between devicesUnshielded cable: <50 m for input
Shielded cable: <10 m for fast input
Shielded cable: <10 m for high speed input
Unshielded cable: <150 m for output
InsulationNon-insulated between inputs
Between output and internal logic at 1780 V AC
Between output groups at 1780 V AC
Between supply and internal logic at 1780 V AC
Between input and internal logic at 500 V AC
Between fast input and internal logic at 500 V AC
Between input groups at 500 V AC
Sensor power supply24 V DC at 300 mA supplied by the controller
MarkingCE
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715
Height90 mm
Depth70 mm
Width225 mm
Net weight0.684 kg
0.684 kg
Environment
IP degree of protectionIP20 with protective cover in place
StandardsIEC 61131-2
IEC 61010-2-201
Electromagnetic compatibilityElectrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to IEC 61000-4-2
Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to IEC 61000-4-3
Magnetic field at power frequency – test level: 30 A/m conforming to IEC 61000-4-8
Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 2 kV (relay output) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (I/O) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (serial link) conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 2 kV (power lines (AC)) conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 2 kV (relay output) conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (I/O) conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (shielded cable) conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 0.5 kV (power lines (DC)) conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (AC)) conforming to IEC 61000-4-5
Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to IEC 61000-4-6
Conducted emission – test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to IEC 55011
Conducted emission – test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to IEC 55011
Radiated emission – test level: 40 dBμV/m QP class A (10 m) conforming to IEC 55011
Radiated emission – test level: 47 dBμV/m QP class A (10 m) conforming to IEC 55011
Electrical fast transient/burst immunity test – test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4
Shock resistance15 gn for 11 ms
30 gn for 6 ms
Immunity to microbreaks10 ms
Vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail
1 gn at 8.4…150 Hz on symmetrical rail
3.5 mm at 5…8.7 Hz on panel mounting
2 gn at 8.7…150 Hz on panel mounting
Relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
Ambient air temperature for operation0…55 °C (horizontal installation)
Ambient air temperature for storage-25…70 °C
Pollution degree<= 2
Operating altitude0…2000 m
Storage altitude0…3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.467 cm
Package 1 Width13.692 cm
Package 1 Length23.764 cm
Package 1 Weight900.5 g
Unit Type of Package 2S03
Number of Units in Package 29
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight8629.5 g
Unit Type of Package 3P12
Number of Units in Package 3216
Package 3 Height95 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight216108 g

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider TM200C60R | Controller M200 60I/O relay”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat