Let's Chat
-45%

Schneider TM221C24R | controller M221 24 IO relay, Logic Controller

Availability:

Out of stock


Schneider TM221C24R | controller M221 24 IO relay, Logic Controller

25,638 EGP 46,615 EGP

Out of stock

Compare

Schneider TM221C24R | controller M221 24 IO relay, Logic Controller

Schneider TM221C24R Logic Controller

Introduction

The Schneider TM221C24R is a compact, yet powerful logic controller from the Modicon M221 series, designed for small to medium-sized automation projects. This controller is part of Schneider Electric’s EcoStruxure Machine Expert, which focuses on providing scalable and flexible solutions for machine control, ensuring high performance and reliability in various industrial applications.

What is the Schneider TM221C24R?

The TM221C24R is a programmable logic controller (PLC) equipped with 24 I/O channels, making it suitable for controlling a variety of machines and processes. The “C” in the model number indicates that it is part of the compact series, and the “R” denotes that it includes relay outputs, which are particularly useful for applications requiring switching of higher currents.

Key Features of Schneider TM221C24R

1. Integrated I/O

The TM221C24R comes with 24 integrated input and output channels, consisting of both digital inputs and relay outputs. This combination allows the controller to handle various control tasks, from simple on/off control to more complex logic operations.

2. Flexible Programming

This logic controller supports multiple programming languages, including Ladder Logic, Structured Text, and Function Block Diagram, all of which can be programmed using Schneider’s EcoStruxure Machine Expert software. This flexibility allows users to program in the language they are most comfortable with.

3. Compact Design

Despite its powerful capabilities, the TM221C24R is designed to be compact, making it ideal for applications where space is limited. Its small footprint allows it to be installed in tight control cabinets without compromising on performance.

4. Communication Capabilities

The TM221C24R features built-in communication ports, including Ethernet and serial connections, allowing it to interface with other devices and systems easily. This makes it suitable for networked control systems and remote monitoring applications.

5. Robust Performance

Built for industrial environments, the TM221C24R is designed to operate reliably under challenging conditions, including temperature extremes, vibration, and electrical noise. Its robust construction ensures long-term performance and minimal maintenance.

Technical Specifications

  • Inputs: 14 Digital Inputs
  • Outputs: 10 Relay Outputs
  • Communication Ports: Ethernet, RS232/RS485
  • Programming Languages: Ladder Logic, Structured Text, Function Block Diagram
  • Memory: 256 kB of internal memory for program storage
  • Mounting: DIN Rail Mounting
  • Operating Temperature: Wide operating temperature range for industrial environments.

Applications of Schneider TM221C24R

  • Machine Control: Ideal for controlling various types of machinery, including packaging machines, conveyors, and more.
  • Process Automation: Suitable for automating industrial processes that require reliable control and monitoring.
  • Building Automation: Can be used in building management systems to control lighting, HVAC, and other systems.
  • Remote Monitoring: The integrated communication capabilities make it ideal for remote monitoring and control applications.

Benefits of Using Schneider TM221C24R

1. High Performance in a Compact Size

The TM221C24R provides powerful control capabilities in a small package, making it ideal for applications where space is a premium. Despite its compact size, it delivers reliable performance for a wide range of control tasks.

2. Versatile Connectivity

With its built-in Ethernet and serial ports, the TM221C24R can easily connect to other devices and networks, enabling seamless integration into existing systems. This connectivity is crucial for modern industrial automation, where devices must communicate efficiently.

3. Ease of Use

Schneider’s EcoStruxure Machine Expert software makes programming the TM221C24R straightforward, even for those new to PLC programming. The software’s user-friendly interface and extensive library of functions help speed up development and reduce programming errors.

Installation Guidelines

  1. Mount the Controller: Attach the TM221C24R to a DIN rail in the control cabinet.
  2. Connect I/O Devices: Wire the digital inputs and relay outputs to the corresponding devices.
  3. Set Up Communication: Connect the Ethernet or serial ports to the network or other devices as needed.
  4. Program the Controller: Use EcoStruxure Machine Expert to develop and upload the control program.
  5. Test the System: Power up the controller and test the program to ensure proper operation.

Conclusion

The Schneider TM221C24R is a versatile and compact logic controller ideal for a wide range of automation applications. Its combination of integrated I/O, flexible programming options, and robust performance makes it an excellent choice for both new installations and system upgrades.

SKU: TM221C24R Category:
brands

Schneider Electric

Main
Range of product Modicon M221
Product or component type Logic controller
[Us] rated supply voltage 100…240 V AC
Discrete input number 14, discrete input conforming to IEC 61131-2 Type 1
Analogue input number 2 at 0…10 V
Discrete output type Relay normally open
Discrete output number 10 relay
Discrete output voltage 5…125 V DC
5…250 V AC
Discrete output current 2 A
Complementary
Discrete I/O number 24
Maximum number of I/O expansion module 7 (local I/O-Architecture)
14 (remote I/O-Architecture)
Supply voltage limits 85…264 V
network frequency 50/60 Hz
Inrush current 40 A
Maximum power consumption in VA 55 VA at 100…240 V with max number of I/O expansion module
32 VA at 100…240 V without I/O expansion module
Power supply output current 0.52 A 5 V for expansion bus
0.16 A 24 V for expansion bus
Discrete input logic Sink or source (positive/negative)
Discrete input voltage 24 V
Discrete input voltage type DC
Analogue input resolution 10 bits
LSB value 10 mV
Conversion time 1 ms per channel + 1 controller cycle time for analogue input analog input
Permitted overload on inputs +/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
Voltage state 1 guaranteed >= 15 V for input
Voltage state 0 guaranteed <= 5 V for input
Discrete input current 7 mA for discrete input
5 mA for fast input
Input impedance 3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
Response time 35 µs turn-off, I2…I5 terminal(s) for input
10 ms turn-on for output
10 ms turn-off for output
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
Configurable filtering time 0 ms for input
3 ms for input
12 ms for input
Output voltage limits 125 V DC
277 V AC
Maximum current per output common 4 A at COM 2
7 A at COM 0
7 A at COM 1
Absolute accuracy error +/- 1 % of full scale for analog input
Electrical durability 100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Switching frequency 20 switching operations/minute with maximum load
Mechanical durability 20000000 cycles for relay output
Minimum load 1 mA at 5 V DC for relay output
Protection type Without protection at 5 A
Reset time 1 s
Memory capacity 256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
Data backed up 256 kB built-in flash memory for backup of application and data
Data storage equipment 2 GB SD card (optional)
Battery type BR2032 or CR2032X lithium non-rechargeable
Backup time 1 year at 25 °C (by interruption of power supply)
Execution time for 1 KInstruction 0.3 ms for event and periodic task
Execution time per instruction 0.2 µs Boolean
Exct time for event task 60 µs response time
Maximum size of object areas 255 %C counters
8000 %MW memory words
512 %M memory bits
512 %KW constant words
255 %TM timers
Realtime clock With
Clock drift <= 30 s/month at 25 °C
Regulation loop Adjustable PID regulator up to 14 simultaneous loops
Counting input number 4 fast input (HSC mode) at 100 kHz 32 bits
counter function A/B
Single phase
Pulse/direction
Integrated connection type USB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS485 interface
Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
Supply (serial)serial link supply: 5 V, <200 mA
Transmission rate 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
Communication port protocol USB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
Local signalling 1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED (green) for SL2
1 LED per channel (green) for I/O state
Electrical connection removable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
Maximum cable distance between devices Shielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
Insulation Between input and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between supply and ground at 1500 V AC
Between sensor power supply and ground at 500 V AC
Between input and ground at 500 V AC
Between output and ground at 1500 V AC
Between supply and internal logic at 2300 V AC
Between sensor power supply and internal logic at 500 V AC
Between output and internal logic at 2300 V AC
Between Ethernet terminal and internal logic at 500 V AC
Between supply and sensor power supply at 2300 V AC
marking CE
Sensor power supply 24 V DC at 250 mA supplied by the controller
Mounting support Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Height 90 mm
Depth 70 mm
Width 110 mm
Net weight 0.395 kg
Environment
Standards IEC 61131-2
UL 508
CAN/CSA C22.2 No. 213
IACS E10
ANSI/ISA 12-12-01
Product certifications LR
ABS
DNV-GL
RCM
cULus
EAC
CE
UKCA
cULus HazLoc
Environmental characteristic Ordinary and hazardous location
Resistance to electrostatic discharge 8 kV in air conforming to IEC 61000-4-2
4 kV on contact conforming to IEC 61000-4-2
Resistance to electromagnetic fields 10 V/m 80 MHz…1 GHz conforming to IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to IEC 61000-4-3
1 V/m 2…2.7 GHz conforming to IEC 61000-4-3
Resistance to magnetic fields 30 A/m 50/60 Hz conforming to IEC 61000-4-8
Resistance to fast transients 2 kV (power lines) conforming to IEC 61000-4-4
2 kV (relay output) conforming to IEC 61000-4-4
1 kV (I/O) conforming to IEC 61000-4-4
1 kV (Ethernet line) conforming to IEC 61000-4-4
1 kV (serial link) conforming to IEC 61000-4-4
Surge withstand 2 kV power lines (AC) common mode conforming to IEC 61000-4-5
2 kV relay output common mode conforming to IEC 61000-4-5
1 kV I/O common mode conforming to IEC 61000-4-5
1 kV shielded cable common mode conforming to IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to IEC 61000-4-5
1 kV relay output differential mode conforming to IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5
Resistance to conducted disturbances 10 V 0.15…80 MHz conforming to IEC 61000-4-6
3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Electromagnetic emission Conducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011
Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011
Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011
Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011
Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011
Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011
Immunity to microbreaks 10 ms
Ambient air temperature for operation -10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
Ambient air temperature for storage -25…70 °C
Relative humidity 10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protection IP20 with protective cover in place
Pollution degree <= 2
Operating altitude 0…2000 m
Storage altitude 0…3000 m
Vibration resistance 3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
Shock resistance 98 m/s² for 11 ms
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 11.116 cm
Package 1 Width 14.219 cm
Package 1 Length 15.643 cm
Package 1 Weight 640.0 g
Unit Type of Package 2 CAR
Number of Units in Package 2 20
Package 2 Height 29.1 cm
Package 2 Width 39.5 cm
Package 2 Length 56.3 cm
Package 2 Weight 13.87 kg
Unit Type of Package 3 P12
Number of Units in Package 3 240
Package 3 Height 120.0 cm
Package 3 Width 105.0 cm
Package 3 Length 80.0 cm
Package 3 Weight 164 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider TM221C24R | controller M221 24 IO relay, Logic Controller”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024