-45%
, , ,

Schneider TM221C24R | controller M221 24 IO relay, Logic Controller

Schneider Electric
Availability:

Out of stock


Schneider TM221C24R | controller M221 24 IO relay, Logic Controller

25,638 EGP 46,615 EGP

Out of stock

Compare

Schneider TM221C24R | controller M221 24 IO relay, Logic Controller

Specifications:

  • Model: TM221C24R

  • Type: Logic Controller

  • Series: Modicon M221

  • I/O Configuration: 24 I/O (16 digital inputs, 8 digital outputs, relay type)

  • Power Supply: 24V DC

  • Programming Language: IEC 61131-3 (Structured Text, Ladder Diagram, Function Block Diagram, Instruction List)

  • Communication Ports: 1x Ethernet (Modbus TCP), 1x USB, 1x CANopen (optional)

  • Mounting Type: DIN rail mountable

  • Relay Outputs: 8 relay outputs (NO, 250VAC, 8A)

  • Digital Inputs: 16 digital inputs (12V DC)

  • Rated Input Voltage: 24V DC

Features:

  1. Compact and Flexible:

    • The Modicon M221 controller is a compact and modular logic controller with 24 I/O channels, designed to provide flexible and cost-effective control solutions for a wide variety of industrial and automation applications.

  2. 24 I/O with Relay Outputs:

    • The TM221C24R comes with 16 digital inputs and 8 relay outputs. The relay outputs are rated for 250VAC, 8A, making it suitable for controlling relays, motors, and other electrical devices. The digital inputs accept 24V DC signals from various sensors and switches.

  3. Powerful and Efficient Logic Control:

    • The Modicon M221 controller is designed to handle complex logic and control tasks while maintaining a compact form factor. It is ideal for small to medium-sized automation systems, providing efficient control and monitoring.

  4. Built-in Communication Ports:

    • The TM221C24R controller features built-in communication ports, including Modbus TCP over Ethernet, USB, and an optional CANopen port. This allows seamless integration into industrial networks and offers versatile connectivity for remote monitoring, data exchange, and programming.

  5. IEC 61131-3 Programming Standard:

    • The controller supports programming languages in line with the IEC 61131-3 standard, including Ladder Diagram (LD), Structured Text (ST), Function Block Diagram (FBD), and Instruction List (IL). This flexibility allows users to program the controller using their preferred language and the requirements of the application.

  6. Easy Integration:

    • The TM221C24R is designed to easily integrate into existing automation systems, making it ideal for upgrading or expanding control systems. Its DIN rail mounting makes installation simple in control panels or enclosures.

  7. Expandability:

    • Although this model features 24 I/O, the Modicon M221 series is modular, allowing for easy expansion by adding additional I/O modules if more I/O capacity is required in the future.

  8. Cost-Effective Solution:

    • The Modicon M221 logic controller provides an affordable solution for automation applications without compromising on performance. It’s well-suited for small and medium-sized control systems, offering both functionality and value for money.

Applications:

  • Industrial Automation: Ideal for small-scale automation projects such as conveyors, packaging machines, or small production lines.

  • Building Automation: Can be used for controlling lighting, HVAC, security systems, and other systems in buildings.

  • Machine Control: Suitable for controlling machines in manufacturing processes, such as motors, actuators, and safety devices.

  • Energy Management: Used in monitoring and controlling energy consumption in industrial and commercial applications.

  • Process Control: Can be used to manage temperature, pressure, flow, and other variables in process control systems.

brands

Main
Range of productModicon M221
Product or component typeLogic controller
[Us] rated supply voltage100…240 V AC
Discrete input number14, discrete input conforming to IEC 61131-2 Type 1
Analogue input number2 at 0…10 V
Discrete output typeRelay normally open
Discrete output number10 relay
Discrete output voltage5…125 V DC
5…250 V AC
Discrete output current2 A
Complementary
Discrete I/O number24
Maximum number of I/O expansion module7 (local I/O-Architecture)
14 (remote I/O-Architecture)
Supply voltage limits85…264 V
network frequency50/60 Hz
Inrush current40 A
Maximum power consumption in VA55 VA at 100…240 V with max number of I/O expansion module
32 VA at 100…240 V without I/O expansion module
Power supply output current0.52 A 5 V for expansion bus
0.16 A 24 V for expansion bus
Discrete input logicSink or source (positive/negative)
Discrete input voltage24 V
Discrete input voltage typeDC
Analogue input resolution10 bits
LSB value10 mV
Conversion time1 ms per channel + 1 controller cycle time for analogue input analog input
Permitted overload on inputs+/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
Voltage state 1 guaranteed>= 15 V for input
Voltage state 0 guaranteed<= 5 V for input
Discrete input current7 mA for discrete input
5 mA for fast input
Input impedance3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
Response time35 µs turn-off, I2…I5 terminal(s) for input
10 ms turn-on for output
10 ms turn-off for output
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
Configurable filtering time0 ms for input
3 ms for input
12 ms for input
Output voltage limits125 V DC
277 V AC
Maximum current per output common4 A at COM 2
7 A at COM 0
7 A at COM 1
Absolute accuracy error+/- 1 % of full scale for analog input
Electrical durability100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Switching frequency20 switching operations/minute with maximum load
Mechanical durability20000000 cycles for relay output
Minimum load1 mA at 5 V DC for relay output
Protection typeWithout protection at 5 A
Reset time1 s
Memory capacity256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
Data backed up256 kB built-in flash memory for backup of application and data
Data storage equipment2 GB SD card (optional)
Battery typeBR2032 or CR2032X lithium non-rechargeable
Backup time1 year at 25 °C (by interruption of power supply)
Execution time for 1 KInstruction0.3 ms for event and periodic task
Execution time per instruction0.2 µs Boolean
Exct time for event task60 µs response time
Maximum size of object areas255 %C counters
8000 %MW memory words
512 %M memory bits
512 %KW constant words
255 %TM timers
Realtime clockWith
Clock drift<= 30 s/month at 25 °C
Regulation loopAdjustable PID regulator up to 14 simultaneous loops
Counting input number4 fast input (HSC mode) at 100 kHz 32 bits
counter functionA/B
Single phase
Pulse/direction
Integrated connection typeUSB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS485 interface
Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
Supply(serial)serial link supply: 5 V, <200 mA
Transmission rate1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
Communication port protocolUSB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
Local signalling1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED (green) for SL2
1 LED per channel (green) for I/O state
Electrical connectionremovable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
Maximum cable distance between devicesShielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
InsulationBetween input and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between supply and ground at 1500 V AC
Between sensor power supply and ground at 500 V AC
Between input and ground at 500 V AC
Between output and ground at 1500 V AC
Between supply and internal logic at 2300 V AC
Between sensor power supply and internal logic at 500 V AC
Between output and internal logic at 2300 V AC
Between Ethernet terminal and internal logic at 500 V AC
Between supply and sensor power supply at 2300 V AC
markingCE
Sensor power supply24 V DC at 250 mA supplied by the controller
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Height90 mm
Depth70 mm
Width110 mm
Net weight0.395 kg
Environment
StandardsIEC 61131-2
UL 508
CAN/CSA C22.2 No. 213
IACS E10
ANSI/ISA 12-12-01
Product certificationsLR
ABS
DNV-GL
RCM
cULus
EAC
CE
UKCA
cULus HazLoc
Environmental characteristicOrdinary and hazardous location
Resistance to electrostatic discharge8 kV in air conforming to IEC 61000-4-2
4 kV on contact conforming to IEC 61000-4-2
Resistance to electromagnetic fields10 V/m 80 MHz…1 GHz conforming to IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to IEC 61000-4-3
1 V/m 2…2.7 GHz conforming to IEC 61000-4-3
Resistance to magnetic fields30 A/m 50/60 Hz conforming to IEC 61000-4-8
Resistance to fast transients2 kV (power lines) conforming to IEC 61000-4-4
2 kV (relay output) conforming to IEC 61000-4-4
1 kV (I/O) conforming to IEC 61000-4-4
1 kV (Ethernet line) conforming to IEC 61000-4-4
1 kV (serial link) conforming to IEC 61000-4-4
Surge withstand2 kV power lines (AC) common mode conforming to IEC 61000-4-5
2 kV relay output common mode conforming to IEC 61000-4-5
1 kV I/O common mode conforming to IEC 61000-4-5
1 kV shielded cable common mode conforming to IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to IEC 61000-4-5
1 kV relay output differential mode conforming to IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5
Resistance to conducted disturbances10 V 0.15…80 MHz conforming to IEC 61000-4-6
3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Electromagnetic emissionConducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011
Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011
Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011
Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011
Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011
Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011
Immunity to microbreaks10 ms
Ambient air temperature for operation-10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
Ambient air temperature for storage-25…70 °C
Relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protectionIP20 with protective cover in place
Pollution degree<= 2
Operating altitude0…2000 m
Storage altitude0…3000 m
Vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
Shock resistance98 m/s² for 11 ms
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.116 cm
Package 1 Width14.219 cm
Package 1 Length15.643 cm
Package 1 Weight640.0 g
Unit Type of Package 2CAR
Number of Units in Package 220
Package 2 Height29.1 cm
Package 2 Width39.5 cm
Package 2 Length56.3 cm
Package 2 Weight13.87 kg
Unit Type of Package 3P12
Number of Units in Package 3240
Package 3 Height120.0 cm
Package 3 Width105.0 cm
Package 3 Length80.0 cm
Package 3 Weight164 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider TM221C24R | controller M221 24 IO relay, Logic Controller”