-45%

Schneider TM221CE16R | controller M221 16 IO relay Ethernet

Schneider Electric
Availability:

Out of stock


Schneider TM221CE16R | controller M221 16 IO relay Ethernet

25,732 EGP 46,786 EGP

Out of stock

Compare

Schneider TM221CE16R | controller M221 16 IO relay Ethernet

Schneider TM221CE16R

Introduction

The Schneider TM221CE16R is a powerful and versatile programmable logic controller (PLC) designed for a wide range of industrial and commercial applications. This device is pivotal in automating processes, enhancing operational efficiency, and ensuring robust performance across various sectors. In this article, we’ll delve into the specifics of the Schneider TM221CE16R, exploring its features, applications, benefits, and more.

What is the Schneider TM221CE16R?

it is a member of the Modicon M221 series, known for its compact size and high performance. This PLC is engineered to meet the demands of complex automation tasks, providing reliable control and monitoring solutions. Key features include:

  • Compact design: Ideal for space-constrained environments.
  • Robust performance: Capable of handling demanding industrial processes.
  • Flexible communication: Supports various communication protocols for seamless integration.

Technical Specifications

Understanding the technical details of the it is crucial for ensuring it meets your specific needs. Here are some key specifications:

  • Inputs/Outputs: 16 digital inputs and outputs, facilitating versatile control options.
  • Communication: Ethernet port for network connectivity, along with Modbus protocol support.
  • Power Requirements: Operates on a 24V DC power supply, ensuring energy efficiency.

Applications of Schneider TM221CE16R

it is employed in numerous industrial and commercial settings, thanks to its flexibility and reliability. Common applications include:

  • Industrial Automation: Streamlining manufacturing processes and improving productivity.
  • Building Management Systems: Enhancing the control of HVAC, lighting, and security systems.
  • Agriculture: Automating irrigation systems and greenhouse climate control.

Benefits of Using Schneider TM221CE16R

Investing in it brings several advantages:

  • Enhanced Efficiency: Automates repetitive tasks, reducing manual labor and errors.
  • Reliability and Durability: Built to withstand harsh industrial environments, ensuring long-term performance.
  • Cost-Effectiveness: Offers a high return on investment through improved operational efficiency and reduced downtime.

Installation and Setup

Setting up the TM221CE16R is straightforward with the right guidance. Here’s a quick overview:

  1. Mount the PLC: Secure the TM221CE16R in a suitable location within your control panel.
  2. Connect Power Supply: Ensure a stable 24V DC power connection.
  3. Wire Inputs and Outputs: Connect sensors, actuators, and other devices to the PLC’s input and output terminals.
  4. Establish Communication: Configure network settings for Ethernet or Modbus communication.

Programming the TM221CE16R

Programming this PLC requires specific software tools and knowledge. Here are the basic steps:

  1. Install SoMachine Software: Schneider’s programming environment for PLCs.
  2. Create a New Project: Define the project parameters and select the TM221CE16R model.
  3. Develop the Control Logic: Use ladder logic or other supported programming languages to create your automation scripts.
  4. Test and Deploy: Simulate the program to check for errors, then deploy it to the PLC.

Integrating TM221CE16R with Other Systems

The TM221CE16R’s flexibility allows it to integrate seamlessly with other systems:

  • Schneider Products: Easily connects with other Schneider devices like HMIs and sensors.
  • Third-Party Systems: Supports standard communication protocols for integration with non-Schneider equipment.
  • Real-World Examples: Used in combination with SCADA systems for comprehensive plant monitoring and control.

Maintenance and Troubleshooting

To ensure the longevity and optimal performance of it, regular maintenance is essential. Here are some tips:

  • Routine Checks: Inspect wiring and connections periodically.
  • Firmware Updates: Keep the PLC’s firmware up to date to benefit from the latest features and security patches.
  • Common Issues: Identify and resolve problems such as communication failures or power supply interruptions promptly.
SKU: TM221CE16R Category:
Main
Range of productModicon M221
product or component typeLogic controller
[Us] rated supply voltage100…240 V AC
Discrete input number9, discrete input conforming to IEC 61131-2 Type 1
Analogue input number2 at 0…10 V
Discrete output typeRelay normally open
Discrete output number7 relay
Discrete output voltage5…125 V DC
5…250 V AC
Discrete output current2 A
Complementary
Discrete I/O number16
Maximum number of I/O expansion module4 (local I/O-Architecture)
11 (remote I/O-Architecture)
Supply voltage limits85…264 V
Network frequency50/60 Hz
Inrush current40 A
Maximum power consumption in VA49 VA at 100…240 V with max number of I/O expansion module
33 VA at 100…240 V without I/O expansion module
Power supply output current0.325 A 5 V for expansion bus
0.12 A 24 V for expansion bus
Discrete input logicSink or source (positive/negative)
Discrete input voltage24 V
discrete input voltage typeDC
analogue input resolution10 bits
LSB value10 mV
Conversion time1 ms per channel + 1 controller cycle time for analogue input analog input
Permitted overload on inputs+/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
Voltage state 1 guaranteed>= 15 V for input
Voltage state 0 guaranteed<= 5 V for input
Discrete input current7 mA for discrete input
5 mA for fast input
Input impedance3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
Response time35 µs turn-off, I2…I5 terminal(s) for input
10 ms turn-on for output
10 ms turn-off for output
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
Configurable filtering time0 ms for input
3 ms for input
12 ms for input
Output voltage limits125 V DC
277 V AC
Maximum current per output common6 A at COM 1
7 A at COM 0
Absolute accuracy error+/- 1 % of full scale for analog input
Electrical durability100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Switching frequency20 switching operations/minute with maximum load
Mechanical durability20000000 cycles for relay output
Minimum load1 mA at 5 V DC for relay output
Protection typeWithout protection at 5 A
Reset time1 s
Memory capacity256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
Data backed up256 kB built-in flash memory for backup of application and data
Data storage equipment2 GB SD card (optional)
Battery typeBR2032 or CR2032X lithium non-rechargeable
Backup time1 year at 25 °C (by interruption of power supply)
Execution time for 1 KInstruction0.3 ms for event and periodic task
Execution time per instruction0.2 µs Boolean
Exct time for event task60 µs response time
Maximum size of object areas255 %C counters
512 %KW constant words
255 %TM timers
512 %M memory bits
8000 %MW memory words
Realtime clockWith
Clock drift<= 30 s/month at 25 °C
Regulation loopAdjustable PID regulator up to 14 simultaneous loops
Counting input number4 fast input (HSC mode) at 100 kHz 32 bits
counter functionPulse/direction
A/B
Single phase
Integrated connection typeUSB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface
Ethernet with RJ45 connector
Supply(Serial)serial link supply: 5 V, <200 mA
Transmission rate1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
Communication port protocolUSB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
Ethernet
Port Ethernet10BASE-T/100BASE-TX 1 port with 100 m copper cable
communication serviceDHCP client
Ethernet/IP adapter
Modbus TCP server
Modbus TCP slave device
Modbus TCP client
Local signalling1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED per channel (green) for I/O state
1 LED (green) for SL
Ethernet network activity (green) for ACT
Ethernet network link (yellow) for Link (Link Status)
Electrical connectionRemovable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
Maximum cable distance between devicesShielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
InsulationBetween input and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between supply and ground at 1500 V AC
Between sensor power supply and ground at 500 V AC
Between input and ground at 500 V AC
Between output and ground at 1500 V AC
Between supply and internal logic at 2300 V AC
Between sensor power supply and internal logic at 500 V AC
Between output and internal logic at 2300 V AC
Between Ethernet terminal and internal logic at 500 V AC
Between supply and sensor power supply at 2300 V AC
markingCE
Sensor power supply24 V DC at 250 mA supplied by the controller
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Height90 mm
Depth70 mm
Width95 mm
net weight0.346 kg
Environment
StandardsIEC 61131-2
UL 508
CAN/CSA C22.2 No. 213
IACS E10
ANSI/ISA 12-12-01
Product certificationscULus
LR
RCM
EAC
ABS
DNV-GL
CE
UKCA
cULus HazLoc
Environmental characteristicOrdinary and hazardous location
Resistance to electrostatic discharge8 kV in air conforming to IEC 61000-4-2
4 kV on contact conforming to IEC 61000-4-2
Resistance to electromagnetic fields10 V/m 80 MHz…1 GHz conforming to IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to IEC 61000-4-3
1 V/m 2…2.7 GHz conforming to IEC 61000-4-3
Resistance to magnetic fields30 A/m 50/60 Hz conforming to IEC 61000-4-8
Resistance to fast transients2 kV (power lines) conforming to IEC 61000-4-4
2 kV (relay output) conforming to IEC 61000-4-4
1 kV (I/O) conforming to IEC 61000-4-4
1 kV (Ethernet line) conforming to IEC 61000-4-4
1 kV (serial link) conforming to IEC 61000-4-4
Surge withstand2 kV power lines (AC) common mode conforming to IEC 61000-4-5
2 kV relay output common mode conforming to IEC 61000-4-5
1 kV I/O common mode conforming to IEC 61000-4-5
1 kV shielded cable common mode conforming to IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to IEC 61000-4-5
1 kV relay output differential mode conforming to IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5
Resistance to conducted disturbances10 V 0.15…80 MHz conforming to IEC 61000-4-6
3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Electromagnetic emissionConducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011
Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011
Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011
Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011
Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011
Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011
Immunity to microbreaks10 ms
Ambient air temperature for operation-10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
ambient air temperature for storage-25…70 °C
Relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protectionIP20 with protective cover in place
Pollution degree<= 2
Operating altitude0…2000 m
Storage altitude0…3000 m
Vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
Shock resistance98 m/s² for 11 ms
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height10.829 cm
Package 1 Width14.04 cm
Package 1 Length14.181 cm
Package 1 Weight590.0 g
Unit Type of Package 2CAR
Number of Units in Package 220
Package 2 Height28.9 cm
Package 2 Width39.5 cm
Package 2 Length57.4 cm
Package 2 Weight12.771 kg
Unit Type of Package 3P12
Number of Units in Package 3240
Package 3 Height105.0 cm
Package 3 Width120.0 cm
Package 3 Length80.0 cm
Package 3 Weight164 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider TM221CE16R | controller M221 16 IO relay Ethernet”