-45%

Schneider TM221CE24R | controller M221 24 IO relay Ethernet

Schneider Electric
Availability:

Out of stock


Schneider TM221CE24R | controller M221 24 IO relay Ethernet

33,294 EGP 60,534 EGP

Out of stock

Compare

Schneider TM221CE24R | controller M221 24 IO relay Ethernet

Schneider TM221CE24R Description

Schneider Electric is a global leader in energy management and automation solutions. Their products are designed to enhance efficiency and sustainability across various industries. One such product is the TM221CE24R, a versatile and robust module that offers extensive capabilities for automation systems. In this article, we will provide a comprehensive overview of the Schneider TM221CE24R, exploring its features, applications, and benefits.

What is the Schneider TM221CE24R?

The Schneider TM221CE24R is a powerful logic controller module designed to optimize and streamline automation processes. It is part of Schneider’s Modicon M221 series, known for its flexibility, performance, and ease of use. This module is ideal for applications requiring reliable control and monitoring capabilities.

Key Features

  • Integrated I/O: Equipped with 14 digital inputs and 10 relay outputs, allowing for extensive control and monitoring.
  • Compact Design: The small footprint makes it easy to integrate into various control panels and systems.
  • High Performance: Ensures fast and accurate processing of control tasks.

Technical Specifications

Understanding the technical specifications of the TM221CE24R is crucial for ensuring it meets your system’s requirements.

Dimensions and Weight

  • Height: 90 mm
  • Width: 150 mm
  • Depth: 60 mm
  • Weight: 300 g

Power Requirements

  • Voltage: 24 V DC
  • Current Consumption: 250 mA

Connectivity Options

  • Communication Ports: Ethernet, Serial (RS485)
  • Input/Output Channels: 14 digital inputs, 10 relay outputs

Installation and Setup

Installing the TM221CE24R is straightforward, but it’s essential to follow the guidelines to ensure optimal performance.

Pre-Installation Requirements

  • Tools Needed: Screwdriver, Multimeter
  • Environmental Conditions: Temperature range of -10°C to 50°C

Step-by-Step Installation Guide

  1. Power Down: Ensure the system is powered down before installation.
  2. Mounting: Secure the module using the provided screws.
  3. Wiring: Connect the input and output wires according to the wiring diagram.
  4. Power Up: Once connected, power up the system and verify proper operation.

Performance and Efficiency

The TM221CE24R module is designed for high performance and efficiency, making it ideal for various automation needs.

Operational Capabilities

  • Processing Speed: High-speed processing for real-time control applications.
  • Load Capacity: Supports up to 2A per output channel

Energy Efficiency

  • Low Power Consumption: Designed to minimize energy usage, contributing to overall system efficiency.

Applications of TM221CE24R

The TM221CE24R module is versatile, making it suitable for a variety of applications across different industries.

Industrial Uses

  • Manufacturing: Enhances automation processes and improves production efficiency.
  • Energy Management: Helps in monitoring and controlling energy usage.

Commercial Applications

  • Building Automation: Integrates with building management systems for improved control.
  • HVAC Systems: Used in heating, ventilation, and air conditioning systems for better performance.

Case Studies

  • Case Study 1: A manufacturing plant improved its production line efficiency by 20% after integrating the TM221CE24R.
  • Case Study 2: A commercial building reduced its energy consumption by 15% using the TM221CE24R in its HVAC system.

Advantages of Using TM221CE24R

Investing in the TM221CE24R module offers several benefits that can significantly enhance your system’s performance.

SKU: TM221CE24R Category:
brands

Main
Range of productModicon M221
Product or component typeLogic controller
[Us] rated supply voltage100…240 V AC
Discrete input number14, discrete input conforming to IEC 61131-2 Type 1
Analogue input number2 at 0…10 V
Discrete output typeRelay normally open
Discrete output number10 relay
Discrete output voltage5…125 V DC
5…250 V AC
Discrete output current2 A
Complementary
Discrete I/O number24
Maximum number of I/O expansion module7 (local I/O-Architecture)
14 (remote I/O-Architecture)
Supply voltage limits85…264 V
Network frequency50/60 Hz
Inrush current40 A
Maximum power consumption in VA58 VA at 100…240 V with max number of I/O expansion module
35 VA at 100…240 V without I/O expansion module
Power supply output current0.52 A 5 V for expansion bus
0.16 A 24 V for expansion bus
Discrete input logicSink or source (positive/negative)
Discrete input voltage24 V
Discrete input voltage typeDC
Analogue input resolution10 bits
LSB value10 mV
Conversion time1 ms per channel + 1 controller cycle time for analogue input analog input
Permitted overload on inputs+/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
Voltage state 1 guaranteed>= 15 V for input
Voltage state 0 guaranteed<= 5 V for input
Discrete input current7 mA for discrete input
5 mA for fast input
Input impedance3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
Response time35 µs turn-off, I2…I5 terminal(s) for input
10 ms turn-on for output
10 ms turn-off for output
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
Configurable filtering time0 ms for input
3 ms for input
12 ms for input
Output voltage limits125 V DC
277 V AC
Maximum current per output common4 A at COM 2
7 A at COM 0
7 A at COM 1
Absolute accuracy error+/- 1 % of full scale for analog input
Electrical durability100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Switching frequency20 switching operations/minute with maximum load
Mechanical durability20000000 cycles for relay output
Minimum load1 mA at 5 V DC for relay output
Protection typeWithout protection at 5 A
Reset time1 s
Memory capacity256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
Data backed up256 kB built-in flash memory for backup of application and data
Data storage equipment2 GB SD card (optional)
Battery typeBR2032 or CR2032X lithium non-rechargeable
Backup time1 year at 25 °C (by interruption of power supply)
Execution time for 1 KInstruction0.3 ms for event and periodic task
Execution time per instruction0.2 µs Boolean
Exct time for event task60 µs response time
Maximum size of object areas255 %TM timers
512 %M memory bits
8000 %MW memory words
255 %C counters
512 %KW constant words
Realtime clockWith
Clock drift<= 30 s/month at 25 °C
Regulation loopAdjustable PID regulator up to 14 simultaneous loops
Counting input number4 fast input (HSC mode) at 100 kHz 32 bits
counter functionA/B
Single phase
Pulse/direction
Integrated connection typeUSB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface
Ethernet with RJ45 connector
Supply(serial)serial link supply: 5 V, <200 mA
Transmission rate1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
Communication port protocolUSB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
Ethernet
Port Ethernet10BASE-T/100BASE-TX 1 port with 100 m copper cable
communication serviceModbus TCP server
Modbus TCP slave device
DHCP client
Modbus TCP client
Ethernet/IP adapter
Local signalling1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED per channel (green) for I/O state
1 LED (green) for SL
Ethernet network activity (green) for ACT
Ethernet network link (yellow) for Link (Link Status)
Electrical connectionremovable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
Maximum cable distance between devicesShielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
InsulationBetween input and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between supply and ground at 1500 V AC
Between sensor power supply and ground at 500 V AC
Between input and ground at 500 V AC
Between output and ground at 1500 V AC
Between supply and internal logic at 2300 V AC
Between sensor power supply and internal logic at 500 V AC
Between output and internal logic at 2300 V AC
Between Ethernet terminal and internal logic at 500 V AC
Between supply and sensor power supply at 2300 V AC
MarkingCE
Sensor power supply24 V DC at 250 mA supplied by the controller
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Height90 mm
Depth70 mm
Width110 mm
Net weight0.395 kg
Environment
StandardsIEC 61131-2
UL 508
CAN/CSA C22.2 No. 213
IACS E10
ANSI/ISA 12-12-01
Product certificationsLR
cULus
ABS
DNV-GL
EAC
RCM
CE
UKCA
cULus HazLoc
Environmental characteristicOrdinary and hazardous location
Resistance to electrostatic discharge8 kV in air conforming to IEC 61000-4-2
4 kV on contact conforming to IEC 61000-4-2
Resistance to electromagnetic fields10 V/m 80 MHz…1 GHz conforming to IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to IEC 61000-4-3
1 V/m 2…2.7 GHz conforming to IEC 61000-4-3
Resistance to magnetic fields30 A/m 50/60 Hz conforming to IEC 61000-4-8
Resistance to fast transients2 kV (power lines) conforming to IEC 61000-4-4
2 kV (relay output) conforming to IEC 61000-4-4
1 kV (I/O) conforming to IEC 61000-4-4
1 kV (Ethernet line) conforming to IEC 61000-4-4
1 kV (serial link) conforming to IEC 61000-4-4
Surge withstand2 kV power lines (AC) common mode conforming to IEC 61000-4-5
2 kV relay output common mode conforming to IEC 61000-4-5
1 kV I/O common mode conforming to IEC 61000-4-5
1 kV shielded cable common mode conforming to IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to IEC 61000-4-5
1 kV relay output differential mode conforming to IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5
Resistance to conducted disturbances10 V 0.15…80 MHz conforming to IEC 61000-4-6
3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Electromagnetic emissionConducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011
Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011
Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011
Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011
Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011
Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011
Immunity to microbreaks10 ms
Ambient air temperature for operation-10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
Ambient air temperature for storage-25…70 °C
Relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protectionIP20 with protective cover in place
Pollution degree<= 2
Operating altitude0…2000 m
Storage altitude0…3000 m
Vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
Shock resistance98 m/s² for 11 ms
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.156 cm
Package 1 Width14.152 cm
Package 1 Length15.681 cm
Package 1 Weight650.0 g
Unit Type of Package 2CAR
Number of Units in Package 220
Package 2 Height29.9 cm
Package 2 Width39.4 cm
Package 2 Length57.5 cm
Package 2 Weight14.171 kg
Unit Type of Package 3P12
Number of Units in Package 3240
Package 3 Height105.0 cm
Package 3 Width120.0 cm
Package 3 Length80.0 cm
Package 3 Weight182 kg

Main Document

Data Sheet : TM221CE24R

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider TM221CE24R | controller M221 24 IO relay Ethernet”