The Schneider Electric TM3TM3 is an analog I/O expansion module from the Modicon TM3 series. Designed for use with Modicon controllers, it offers reliable analog signal processing with flexible input/output configurations for a variety of industrial control and automation applications.

Key Features

  • Product Type: Analog I/O expansion module

  • Series: Modicon TM3

  • Input Channels:

    • 2 configurable analog or temperature inputs

  • Output Channels:

    • 1 analog output

  • Signal Type: Voltage or current for analog; PT100, PT1000, or thermocouples for temperature

  • Connection Type: Screw terminals

Electrical Specifications

  • Power Supply: 24V DC

  • Input Resolution: 12-bit (typical, depending on configuration)

  • Output Resolution: 12-bit analog signal

  • Input Range Options:

    • Voltage: 0–10 V

    • Current: 0–20 mA or 4–20 mA

    • Temperature: PT100, PT1000, J, K, T thermocouples

  • Output Range:

    • Voltage or current (0–10 V, 4–20 mA, etc.)

Mechanical & Environmental Characteristics

  • Mounting: DIN rail, direct attachment to TM3-compatible PLCs

  • Enclosure: Compact plastic housing

  • Operating Temperature: 0°C to +55°C

  • Storage Temperature: -40°C to +70°C

  • Protection Rating: IP20 (module body)

Compatibility

  • Compatible Controllers: Modicon M221, M241, M251, and other TM3-ready devices

  • Expansion Method: Plug-in to the right side of the main controller or existing I/O modules

Applications

  • Process control and monitoring

  • Temperature regulation systems

  • Industrial automation for machines and equipment

  • HVAC systems and energy management

  • Analog sensor integration in PLC-based systems

Advantages

  • Flexible analog input configuration (voltage, current, or temperature)

  • Precise analog output for control systems

  • Easy integration with TM3 and Modicon PLC platforms

  • Compact design for space-saving installations

  • Ideal for mixed analog and digital control environments

SKU: TM3TM3 Categories: , Brand:
Main
range of productModicon TM3
Product or component typeInput/output analog module
Range compatibilityModicon M221
Modicon M241
Modicon M251
Modicon M262
analogue input number2
Analogue input typeCurrent 4…20 mA
current 0…20 mA
voltage 0…10 V
voltage – 10…10 V
thermocouple – 200…1000 °C with thermocouple J
thermocouple – 200…1300 °C with thermocouple K
thermocouple 0…1760 °C with thermocouple R
thermocouple 0…1760 °C with thermocouple S
thermocouple 0…1820 °C with thermocouple B
thermocouple – 200…400 °C with thermocouple T
thermocouple – 200…1300 °C with thermocouple N
thermocouple – 200…800 °C with thermocouple E
thermocouple 0…2315 °C with thermocouple C
Ni 100/Ni 1000 temperature probe – 60…180 °C
Pt 100 temperature probe – 200…850 °C
Pt 1000 temperature probe – 200…600 °C
analogue output number1
Analogue output typeCurrent: 4…20 mA
Current: 0…20 mA
Voltage: 0…10 V
Voltage: – 10…10 V
Complementary
Analogue input resolution16 bits
15 bits + sign
Permissible continuous overload13 V, analogue input type: voltage
40 mA, analogue input type: current
Input impedance<= 50 Ohm current >= 1 MOhm voltage
>= 1 MOhm thermocouple
>= 1 MOhm temperature probe
Analogue output resolution12 bits
LSB value0.15 mV 0…10 Vvoltage
0.30 mV – 10…10 Vvoltage
0.30 µA 0…20 mAcurrent
0.244 µA 4…20 mAcurrent
0.1 °Ctemperature probe
0.1 °Cthermocouple
2.44 mV 0…10 V voltage
4.88 mV – 10…10 V voltage
4.88 µA 0…20 mA current
3.91 µA 4…20 mA current
Load typeResistive
Load impedance ohmic1 kOhm voltage
300 Ohm current
Stabilisation time1 ms
Conversion time100 ms + 100 ms per channel + 1 controller cycle time for analogue input thermocouple
100 ms + 100 ms per channel + 1 controller cycle time for analogue input temperature probe
10 ms + 10 ms per channel + 1 controller cycle time for analogue input voltage/current
Sampling duration10 ms, analogue input type: voltage/current
100 ms, analogue input type: voltage/current
100 ms, analogue input type: thermocouple
100 ms, analogue input type: temperature probe
Absolute accuracy error+/- 6 °C at 25 °C for thermocouple R, S 0…200 °C
+/- 0.4 % of full scale at 25 °C for thermocouple K – 200…0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple J – 200…0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple E – 200…0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple T – 200…0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple N – 200…0 °C
+/- 0.1 % of full scale at 25 °C for analogue input voltage/current
+/- 0.1 % of full scale at 25 °C for thermocouple C 0…2315 °C
+/- 0.1 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe
+/- 0.1 % of full scale at 25 °C for thermocouple R, S 200…1760 °C
+/- 0.1 % of full scale at 25 °C for thermocouple B 300…1820 °C
+/- 0.1 % of full scale at 25 °C for thermocouple K 0…1300 °C
+/- 0.1 % of full scale at 25 °C for thermocouple J 0…1000 °C
+/- 0.1 % of full scale at 25 °C for thermocouple E 0…800 °C
+/- 0.1 % of full scale at 25 °C for thermocouple T 0…400 °C
+/- 0.1 % of full scale at 25 °C for thermocouple N 0…1300 °C
+/- 0.1 % of full scale at 25 °C for analogue output voltage/current
Temperature drift+/- 0.006 %FS/°C
Repeat accuracy+/-0.5 %FS for input
+/- 0.4 %FS for output
Non-linearity+/- 0.01 %FS, analogue output type: analog output
+/- 0.1 %FS, analogue input type: analog input
Output ripple20 mV
Cross talk<= 1 LSB
[Us] rated supply voltage24 V DC
Supply voltage limits20.4…28.8 V
Type of cableTwisted shielded pairs cable <30 m for input/output circuit
Current consumption55 mA at 24 V DC via external supply no load
55 mA at 5 V DC via bus connector no load
60 mA at 5 V DC via bus connector full load
80 mA at 24 V DC via external supply full load
Local signalling1 LED (green) for PWR
Electrical connection11 x 2.5 mm² removable screw terminal block with pitch 5.08 mm adjustment for inputs, outputs and supply
InsulationBetween input and supply at 1500 V AC
Between input and internal logic at 500 V AC
Between output and supply at 1500 V AC
Between output and internal logic at 500 V AC
MarkingCE
Surge withstand1 kV power supply common mode conforming to IEC 61000-4-5
0.5 kV power supply differential mode conforming to IEC 61000-4-5
1 kV I/O common mode conforming to IEC 61000-4-5
0.5 kV I/O differential mode conforming to IEC 61000-4-5
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
height90 mm
Depth70 mm
Width23.6 mm
Net weight0.115 kg
Environment
StandardsIEC 61131-2
product certificationsCE
UKCA
RCM
EAC
cULus
cULus HazLoc
Resistance to electrostatic discharge8 kV in air conforming to IEC 61000-4-2
4 kV on contact conforming to IEC 61000-4-2
Resistance to electromagnetic fields10 V/m 80 MHz…1 GHz conforming to IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to IEC 61000-4-3
1 V/m 2 GHz…3 GHz conforming to IEC 61000-4-3
Resistance to magnetic fields30 A/m conforming to IEC 61000-4-8
Resistance to fast transients1 kV (I/O) conforming to IEC 61000-4-4
Resistance to conducted disturbances10 V 0.15…80 MHz conforming to IEC 61000-4-6
3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Electromagnetic emissionRadiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 230…1000 MHz conforming to IEC 55011
Immunity to microbreaks10 ms
Ambient air temperature for operation-10…55 °C horizontal installation
-10…35 °C vertical installation
Ambient air temperature for storage-25…70 °C
Relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protectionIP20
Pollution degree2
Operating altitude0…2000 m
Storage altitude0…3000 m
Vibration resistance3.5 mm at 5…8.4 Hz on DIN rail
3 gn at 8.4…150 Hz on DIN rail
Shock resistance15 gn for 11 ms
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.611 cm
Package 1 Width10.688 cm
Package 1 Length12.753 cm
Package 1 Weight220.0 g
Unit Type of Package 2S04
Number of Units in Package 242
Package 2 Height30 cm
Package 2 Width40 cm
Package 2 Length60 cm
Package 2 Weight10.421 kg
Unit Type of Package 3P12
Number of Units in Package 3504
Package 3 Height105 cm
Package 3 Width120 cm
Package 3 Length80 cm
Package 3 Weight130 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider TM3TM3 | analog IO module, Modicon TM3, 2 analog or temperature inputs, 1 analog output, screw, 24V DC”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat