Control station type |
Double insulated |
Enclosure material |
Polypropylene |
Electrical circuit type |
Control circuit |
enclosure type |
Complete ready for use |
Control station application |
Control of 2-speed hoist motor |
Control station composition |
2 push-buttons + 1 emergency stop |
Control button type |
Stop push-button Ø 30 mm 1 NC latching
First push-button 1 NC + 2 NO raise, slow-fast
Second push-button 1 NC + 2 NO lower, slow-fast |
Product compatibility |
ZB2BE102 for emergency stop
XENG1191 for each direction |
Mechanical interlocking |
With mechanical interlocking |
Control station colour |
Yellow |
Connections – terminals |
Screw clamp terminals, 1 x 0.5…1 x 2.5 mm² without cable end
Screw clamp terminals, 1 x 0.5…2 x 1.5 mm² with cable end |
Standards |
UL 508
CSA C22.2 No 14
EN/IEC 60947-5-1
EN/IEC 60204-32 |
product certifications |
CCC
GOST |
Protective treatment |
TH |
ambient air temperature for operation |
-25…70 °C |
Ambient air temperature for storage |
-40…70 °C |
Vibration resistance |
15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
Shock resistance |
100 gn conforming to IEC 60068-2-27 |
Overvoltage category |
Class II conforming to IEC 61140 |
IP degree of protection |
IP65 conforming to IEC 60529 |
IK degree of protection |
IK08 conforming to EN 50102 |
Mechanical durability |
1000000 cycles |
Cable entry |
Rubber sleeve with stepped entry 8…26 mm |
Contact code designation |
A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A |
[Ithe] conventional enclosed thermal current |
10 A |
[Ui] rated insulation voltage |
600 V (pollution degree 3) |
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947-1 |
contact operation |
Slow-break
Staggered |
Maximum resistance across terminals |
25 MOhm |
Operating force |
18 N push-button
8 N emergency stop |
Short-circuit protection |
10 A fuse protection by cartridge fuse type gG |
Rated operational power in W |
40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C |
Terminals description ISO n°1 |
(21-22)NC
(13-14)NO
(33-34)NO_CL |
Terminals description ISO n°2 |
(11-12)NC |
Terminal identifier |
(13-14)NO
(11-12)NC |
Net weight |
0.57 kg |