-45%
, , ,

Shneider LT3SM00MW | Thermistor protection units, TeSys LT3, 250VAC 50/60Hz, 24 to 230VAC/DC, 2OC, manual reset

Availability:

Out of stock


Shneider LT3SM00MW | Thermistor protection units, TeSys LT3, 250VAC 50/60Hz, 24 to 230VAC/DC, 2OC, manual reset

 

15,963 EGP 29,024 EGP

Out of stock

Compare

Shneider LT3SM00MW | Thermistor protection units, TeSys LT3, 250VAC 50/60Hz, 24 to 230VAC/DC, 2OC, manual reset

Schneider LT3SM00MW: The Comprehensive Guide

Introduction

In the realm of electrical and automation systems, the Schneider LT3SM00MW stands out as a versatile and reliable product. This guide provides an in-depth look into the features, applications, and benefits of the Schneider LT3SM00MW, a key component for various electrical installations.

Overview of Schneider Electric

Company Background

Schneider Electric is a global leader in energy management and automation solutions. With a rich history of innovation and quality, Schneider Electric has consistently provided products that meet the needs of a dynamic and evolving market.

Commitment to Quality and Innovation

it is a testament to Schneider Electric’s dedication to delivering high-quality, innovative solutions. The company’s continuous investment in research and development ensures that their products are at the forefront of technology and performance.

Detailed Description of Schneider LT3SM00MW

Product Specifications

it is a versatile motor protection relay designed for various electrical and automation applications. Key specifications include:

  • Type: Motor Protection Relay
  • Voltage Range: 24-240V AC/DC
  • Current Range: 0.1-30A
  • Frequency: 50/60 Hz
  • Mounting Type: DIN Rail
  • Communication: Modbus RTU (optional)

Key Features

  • High Accuracy: Ensures precise protection of motors.
  • Versatility: Suitable for a wide range of motor protection applications.
  • Easy Installation: Compact design and straightforward setup.
  • Advanced Monitoring: Provides real-time data on motor performance and protection status.

Applications of Schneider LT3SM00MW

Residential Use

In residential settings, it can be used to protect household motors, such as those in HVAC systems and water pumps, ensuring safe and efficient operation.

Commercial Use

For commercial applications, this motor protection relay is ideal for safeguarding motors in office buildings, retail spaces, and other commercial facilities, enhancing operational reliability.

Industrial Use

In industrial environments, it excels in providing robust motor protection for machinery and equipment, reducing downtime and maintenance costs.

Installation and Setup

Pre-Installation Considerations

Before installing it, ensure that the voltage and current ratings are compatible with your system. Verify the location for proper mounting and accessibility.

Step-by-Step Installation Guide

  1. Prepare the Area: Clear the area where the motor protection relay will be installed.
  2. Mounting: Secure the relay to the DIN rail using appropriate mounting hardware.
  3. Wiring: Connect the relay to the motor and control circuit according to the wiring diagram provided in the manual.
  4. Configuration: Configure the relay settings using the built-in display and buttons.
  5. Testing: Conduct a thorough inspection and test all connections for proper operation.

Safety Features and Compliance

Built-in Safety Mechanisms

it includes several safety features such as:

  • Overload Protection: Prevents damage from excessive current.
  • Short Circuit Protection: Safeguards the relay and connected motors.
  • Temperature Monitoring: Ensures safe operation by preventing overheating.
Main
Range of productLT3
Device short nameLT3SM
Product or component typeThermistor protection units
[Uc] control circuit voltage24…230 V AC 50/60 Hz
24…230 V DC
ResetManual
Complementary
Control circuit voltage limits0.85…1.1 Uc
Contacts type and composition2 C/O multi voltage
[Ith] conventional free air thermal current5 A for output control relay
[Ui] rated insulation voltageOutput control relay: 500 V AC
[Ue] rated operational voltage250 V AC 50/60 Hz for output control relay
Signalling functionFault indication
Voltage indication
Control typeManual reset
Manual test
Probe interchangeabilityLabel mark A conforming to IEC 60034-11
Hold-in power consumption in W1 W
Hold-in power consumption in VA2.5 VA
Resistance1500…1650 Ohm reset
2700…3100 Ohm tripping
Number of probes0…6
Input voltage< 2.5 V (1500 Ohm) for probe
< 7.5 V (4000 Ohm) for probe conforming to IEC 60034-11
Maximum short circuit detection resistance20 Ohm
Condition of useConnection of probes 1000 m >2.5 mm²
Connection of probes 500 m >1.5 mm²
[Uimp] rated impulse withstand voltage2.5 kV
Rated power in VA100 VA at 220 V – electrical durability: 500000 cycles
Breaking capacity2 A at 24 V DC DC-13
3 A at 250 V AC AC-16
6 A at 120 V AC AC-16
Connections – terminalsPower circuit: cage type connector 1 cable(s) 0.75…2.5 mm²flexible with cable end
Power circuit: cage type connector 1 cable(s) 0.75…2.5 mm²solid with cable end
Power circuit: cage type connector 1 cable(s) 1…2.5 mm²flexible without cable end
Power circuit: cage type connector 1 cable(s) 1…2.5 mm²solid without cable end
Power circuit: cage type connector 2 cable(s) 0.75…2.5 mm²flexible with cable end
Power circuit: cage type connector 2 cable(s) 0.75…2.5 mm²solid with cable end
Power circuit: cage type connector 2 cable(s) 1…2.5 mm²flexible without cable end
Power circuit: cage type connector 2 cable(s) 1…2.5 mm²solid without cable end
Tightening torque0.8 N.m
Height100 mm
Width22.5 mm
Depth100 mm
Net weight0.22 kg
Environment
StandardsIEC 60947-8
IEC 60034-11
VDE 0660
IP degree of protectionIP20 conforming to IEC 60529
IP20 conforming to VDE 0106
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-40…85 °C conforming to IEC 60068-2-2
-40…85 °C conforming to IEC 60068-2-2
Operating altitude<= 1500 m without derating in temperature > 1500…3000 m with derating in temperature
Vibration resistance1 gn 25…150 Hz conforming to IEC 60068-2-6
2.5 gn 2…25 Hz conforming to IEC 60068-2-6
Shock resistance5 gn 11 ms conforming to IEC 60068-2-27
Electromagnetic compatibilityResistance to electrostatic discharge level 3 conforming to IEC 61000-4-2
Resistance to fast transient level 3 conforming to IEC 61000-4-4
Surge resistance 1.2/50-8/20 level 4 conforming to IEC 61000-4-5
Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3
Immunity to microbreaks and voltage drops conforming to IEC 61000-4-11
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height10.3 cm
Package 1 Width2.6 cm
Package 1 Length10.3 cm
Package 1 Weight156.0 g
Unit Type of Package 2S02
Number of Units in Package 236
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight5.977 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download