Shneider LT3SM00MW | Thermistor protection units, TeSys LT3, 250VAC 50/60Hz, 24 to 230VAC/DC, 2OC, manual reset

Schneider Electric
Availability:

Out of stock


Shneider LT3SM00MW | Thermistor protection units, TeSys LT3, 250VAC 50/60Hz, 24 to 230VAC/DC, 2OC, manual reset

 

15,963 EGP 29,024 EGP

Out of stock

Compare

Shneider LT3SM00MW | Thermistor protection units, TeSys LT3, 250VAC 50/60Hz, 24 to 230VAC/DC, 2OC, manual reset

Schneider LT3SM00MW: The Comprehensive Guide

Introduction

In the realm of electrical and automation systems, the Schneider LT3SM00MW stands out as a versatile and reliable product. This guide provides an in-depth look into the features, applications, and benefits of the Schneider LT3SM00MW, a key component for various electrical installations.

Overview of Schneider Electric

Company Background

Schneider Electric is a global leader in energy management and automation solutions. With a rich history of innovation and quality, Schneider Electric has consistently provided products that meet the needs of a dynamic and evolving market.

Commitment to Quality and Innovation

it is a testament to Schneider Electric’s dedication to delivering high-quality, innovative solutions. The company’s continuous investment in research and development ensures that their products are at the forefront of technology and performance.

Detailed Description of Schneider LT3SM00MW

Product Specifications

it is a versatile motor protection relay designed for various electrical and automation applications. Key specifications include:

  • Type: Motor Protection Relay
  • Voltage Range: 24-240V AC/DC
  • Current Range: 0.1-30A
  • Frequency: 50/60 Hz
  • Mounting Type: DIN Rail
  • Communication: Modbus RTU (optional)

Key Features

  • High Accuracy: Ensures precise protection of motors.
  • Versatility: Suitable for a wide range of motor protection applications.
  • Easy Installation: Compact design and straightforward setup.
  • Advanced Monitoring: Provides real-time data on motor performance and protection status.

Applications of Schneider LT3SM00MW

Residential Use

In residential settings, it can be used to protect household motors, such as those in HVAC systems and water pumps, ensuring safe and efficient operation.

Commercial Use

For commercial applications, this motor protection relay is ideal for safeguarding motors in office buildings, retail spaces, and other commercial facilities, enhancing operational reliability.

Industrial Use

In industrial environments, it excels in providing robust motor protection for machinery and equipment, reducing downtime and maintenance costs.

Installation and Setup

Pre-Installation Considerations

Before installing it, ensure that the voltage and current ratings are compatible with your system. Verify the location for proper mounting and accessibility.

Step-by-Step Installation Guide

  1. Prepare the Area: Clear the area where the motor protection relay will be installed.
  2. Mounting: Secure the relay to the DIN rail using appropriate mounting hardware.
  3. Wiring: Connect the relay to the motor and control circuit according to the wiring diagram provided in the manual.
  4. Configuration: Configure the relay settings using the built-in display and buttons.
  5. Testing: Conduct a thorough inspection and test all connections for proper operation.

Safety Features and Compliance

Built-in Safety Mechanisms

it includes several safety features such as:

  • Overload Protection: Prevents damage from excessive current.
  • Short Circuit Protection: Safeguards the relay and connected motors.
  • Temperature Monitoring: Ensures safe operation by preventing overheating.
SKU: LT3SM00MW Category:
Main
Range of product LT3
Device short name LT3SM
Product or component type Thermistor protection units
[Uc] control circuit voltage 24…230 V AC 50/60 Hz
24…230 V DC
Reset Manual
Complementary
Control circuit voltage limits 0.85…1.1 Uc
Contacts type and composition 2 C/O multi voltage
[Ith] conventional free air thermal current 5 A for output control relay
[Ui] rated insulation voltage Output control relay: 500 V AC
[Ue] rated operational voltage 250 V AC 50/60 Hz for output control relay
Signalling function Fault indication
Voltage indication
Control type Manual reset
Manual test
Probe interchangeability Label mark A conforming to IEC 60034-11
Hold-in power consumption in W 1 W
Hold-in power consumption in VA 2.5 VA
Resistance 1500…1650 Ohm reset
2700…3100 Ohm tripping
Number of probes 0…6
Input voltage < 2.5 V (1500 Ohm) for probe
< 7.5 V (4000 Ohm) for probe conforming to IEC 60034-11
Maximum short circuit detection resistance 20 Ohm
Condition of use Connection of probes 1000 m >2.5 mm²
Connection of probes 500 m >1.5 mm²
[Uimp] rated impulse withstand voltage 2.5 kV
Rated power in VA 100 VA at 220 V – electrical durability: 500000 cycles
Breaking capacity 2 A at 24 V DC DC-13
3 A at 250 V AC AC-16
6 A at 120 V AC AC-16
Connections – terminals Power circuit: cage type connector 1 cable(s) 0.75…2.5 mm²flexible with cable end
Power circuit: cage type connector 1 cable(s) 0.75…2.5 mm²solid with cable end
Power circuit: cage type connector 1 cable(s) 1…2.5 mm²flexible without cable end
Power circuit: cage type connector 1 cable(s) 1…2.5 mm²solid without cable end
Power circuit: cage type connector 2 cable(s) 0.75…2.5 mm²flexible with cable end
Power circuit: cage type connector 2 cable(s) 0.75…2.5 mm²solid with cable end
Power circuit: cage type connector 2 cable(s) 1…2.5 mm²flexible without cable end
Power circuit: cage type connector 2 cable(s) 1…2.5 mm²solid without cable end
Tightening torque 0.8 N.m
Height 100 mm
Width 22.5 mm
Depth 100 mm
Net weight 0.22 kg
Environment
Standards IEC 60947-8
IEC 60034-11
VDE 0660
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to VDE 0106
Ambient air temperature for operation -25…60 °C
Ambient air temperature for storage -40…85 °C conforming to IEC 60068-2-2
-40…85 °C conforming to IEC 60068-2-2
Operating altitude <= 1500 m without derating in temperature > 1500…3000 m with derating in temperature
Vibration resistance 1 gn 25…150 Hz conforming to IEC 60068-2-6
2.5 gn 2…25 Hz conforming to IEC 60068-2-6
Shock resistance 5 gn 11 ms conforming to IEC 60068-2-27
Electromagnetic compatibility Resistance to electrostatic discharge level 3 conforming to IEC 61000-4-2
Resistance to fast transient level 3 conforming to IEC 61000-4-4
Surge resistance 1.2/50-8/20 level 4 conforming to IEC 61000-4-5
Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3
Immunity to microbreaks and voltage drops conforming to IEC 61000-4-11
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 10.3 cm
Package 1 Width 2.6 cm
Package 1 Length 10.3 cm
Package 1 Weight 156.0 g
Unit Type of Package 2 S02
Number of Units in Package 2 36
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 5.977 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0