UNI-T UT572 Advanced Earth Resistance Tester

UNI-T

  • Power Equipment Grounding Testing.
  • Lightning Protection System Testing.
  • Soil Resistivity Survey.
  • Electrical Installation Inspection.
  • Industrial Grounding Network Testing.
  • Field Earth Resistance Evaluation.

18,000.00 EGP

UNI-T UT572 Advanced Earth Resistance Tester

The UNI-T UT572 Advanced Earth Resistance Tester is a professional-grade instrument designed for accurately measuring earth resistance and soil resistivity in various grounding systems. Suitable for 2-wire, 3-wire, and 4-wire test configurations, the UT572 offers versatile application across different field environments such as power distribution, lightning protection installations, and grounding networks. It automatically detects connection status, interference voltage, and frequency, ensuring reliable results even in challenging testing conditions.

  • 2-wire, 3-wire, and 4-wire earth resistance testing.
  • Earth resistance and soil resistivity measurements.
  • Automatic interface connection check.
  • Interference voltage and frequency detection.
  • Compensation resistance (RK), RH, and RS test modes.
  • Power Equipment Grounding Testing.
  • Lightning Protection System Testing.
  • Soil Resistivity Survey.
  • Electrical Installation Inspection.
  • Industrial Grounding Network Testing.
  • Field Earth Resistance Evaluation.
SKU: UT572 Category: Brand:
brands

Parameter Specification
Earth Resistance (Re): Ranges: 4Ω, 40Ω, 400Ω, 4kΩ, 40kΩ; Accuracy: ±(3%+5)
Soil Resistivity (ρ): Same ranges as above; Accuracy: ±(3%+5)
Compensation Resistance (RK):   Accuracy: ±(3%+15)
RH and RS Testing: Accuracy: ±(3%+15)
Disturbance Voltage (Ust): Up to 50 V (DC/40Hz–500Hz); Accuracy: ±(3%+3)
Disturbance Frequency (Fst): 40Hz–500Hz; Accuracy: ±(1%+2)
Test Frequency: 94 Hz / 128 Hz
Soil Resistivity Test Distance: 1–40 meters
Data Storage: 20 sets
Display: LCD with backlight
Auto Power-Off: Yes
Low Battery Indication: ≤9.5 V
Safety Rating: CAT III 600 V
Certifications: CE, UKCA
Parameter Specification
Earth Resistance (Re): Ranges: 4Ω, 40Ω, 400Ω, 4kΩ, 40kΩ; Accuracy: ±(3%+5)
Soil Resistivity (ρ): Same ranges as above; Accuracy: ±(3%+5)
Compensation Resistance (RK):   Accuracy: ±(3%+15)
RH and RS Testing: Accuracy: ±(3%+15)
Disturbance Voltage (Ust): Up to 50 V (DC/40Hz–500Hz); Accuracy: ±(3%+3)
Disturbance Frequency (Fst): 40Hz–500Hz; Accuracy: ±(1%+2)
Test Frequency: 94 Hz / 128 Hz
Soil Resistivity Test Distance: 1–40 meters
Data Storage: 20 sets
Display: LCD with backlight
Auto Power-Off: Yes
Low Battery Indication: ≤9.5 V
Safety Rating: CAT III 600 V
Certifications: CE, UKCA

Datasheet

Datasheet

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UNI-T UT572 Advanced Earth Resistance Tester”

There are no reviews yet.

SHOPPING CART

close